{"title":"Homepage collection","description":"\u003cp\u003e\u003cstrong\u003eODF Film Forming Machine\u003c\/strong\u003e\u003cbr\u003eEngineered for the simultaneous coating of multiple APIs, our machine streamlines the production of complex combination drugs with precision and\u003cbr\u003eefficiency. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eODF Film Cutting \u0026amp; Packaging Machine\u003c\/strong\u003e\u003cbr\u003eesigned for precise cutting and efficient packaging, our machine ensures seamless processing of ODF films, optimizing production speed and quality\u003c\/p\u003e","products":[{"product_id":"rcz-12a-intelligent-pharmaceutical-dissolution-tester","title":"RCZ-12A Intelligent Pharmaceutical Dissolution Tester - Advanced Drug Dissolution Testing","description":"\u003c!-- PRODUCT_ID: 7815939358777 --\u003e\n\u003c!-- TITLE: RCZ-12A Intelligent Pharmaceutical Dissolution Tester - Advanced Drug Dissolution Testing --\u003e\n\u003ch2\u003e\n\u003ca name=\"_Toc187362377\"\u003e\u003c\/a\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan\u003eDissolution Instruments\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eRCZ-12A Intelligent Pharmaceutical Dissolution Tester\u003c\/p\u003e\n\n\u003cp\u003eThe RCZ-12A is a high-throughput pharmaceutical testing instrument designed for large-scale dissolution testing. With capacity for up to 12 vessels, it supports efficient testing in pharmaceutical manufacturing and research labs. This dissolution tester is USP-compliant and ideal for batch testing and quality assurance.\u003c\/p\u003e\n\u003cdiv style=\"background:#f0f7ff;border-left:4px solid #1a5fb4;padding:14px 20px;margin:18px 0;border-radius:4px;\"\u003e\n  \u003cstrong\u003eInterested in the RCZ-12A?\u003c\/strong\u003e\u003cbr\u003e\n  \u003ca href=\"\/pages\/contact\" style=\"color:#1a5fb4;font-weight:600;text-decoration:none;\"\u003e\n    Request a quote, spec sheet or compliance documentation →\n  \u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eDescription\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eThe RCZ-12A Intelligent Pharmaceutical Dissolution Tester is designed in full compliance with the latest \u003cb\u003eChinese Pharmacopoeia\u003c\/b\u003e and \u003cb\u003eUnited States Pharmacopeia\u003c\/b\u003e standards, as well as the \u003cb\u003eMechanical Validation Guidelines for Dissolution Testers\u003c\/b\u003e. This advanced 12-channel dissolution system ensures high precision and complete data integrity. It is compatible with the ZQY-12A automatic sampling system for seamless operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eProduct Features\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003e1. Advanced Data Management\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eBuilt-in three-tier user permissions, audit trails, and test record management.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eUSB connectivity supports direct test data export for reporting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eFrequently used data storage for quick and easy access.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eSampling solutions can be saved and reused conveniently.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003e2. High-Precision Dissolution Control\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eReal-time temperature control with independent measurements for each dissolution cup.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eDual-layer temperature protection ensures stability and reliability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003ePreheating functionality allows users to schedule start times for heating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003e3. Automated and Modular Design\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eSupports both manual and automatic drug addition and sampling.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eModular design for sampling components enables quick replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003e4. Optimized Sampling System\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eSeparate sampling and tray systems avoid cross-contamination.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eVapor condensation design minimizes evaporation loss.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eAdvanced circulation pipeline with professional quick-release connectors.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003e5. Compliance and Certification\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eFully compliant with pharmacopoeia standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eIncludes IQ\/OQ certification documentation for validation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpFirst\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eModel\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eRCZ-12A\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eProduct Number\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e10100109\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eDissolution Channels\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e12 channels\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eSwing Radius Accuracy\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e≤0.5mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eRotation Speed Deviation\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e≤1.0mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eAxial Deviation\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e≤1.0mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eSpeed Range\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e10–300 RPM\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eStability\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e≤1%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eAdjustment Range\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eRoom temperature to 45.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eTemperature Uniformity\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e0.1°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eControl Precision\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e±0.3°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eSampling Volume\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u0026lt;100ml\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eSampling Time\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e≤999.9h\/59min59s\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003ePower Supply\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eAC220V±10%, 50Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\" style=\"margin-top: 15px\"\u003e\n\u003cspan\u003e\n\u003cb\u003eNote:\u003c\/b\u003e Our lab instruments support basic audit trails strictly per USP\/ChP standards.\n  \u003c\/span\u003e\n\u003c\/p\u003e\n\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What pharmacopoeial standard governs dissolution testing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Dissolution testing is governed by \u003cstrong\u003eUSP \u0026lt;711\u0026gt;\u003c\/strong\u003e (United States Pharmacopeia), \u003cstrong\u003eChP 0931\u003c\/strong\u003e (Chinese Pharmacopoeia), and \u003cstrong\u003ePh.Eur. 2.9.3\u003c\/strong\u003e (European Pharmacopoeia). All Huanghai RCZ-series dissolution testers are designed to comply with USP \u0026lt;711\u0026gt; paddle and basket methods, meeting the ±0.5 rpm speed tolerance and ±0.5°C temperature control requirements. For international market access, verify which pharmacopoeia your target regulatory body recognizes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many dissolution channels do I need for a QC lab?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Channel selection depends on your batch size and testing throughput. A \u003ca href=\"https:\/\/drugmachines.com\/products\/rcz-6n-intelligent-pharmaceutical-dissolution-tester\"\u003e6-channel tester (RCZ-6N)\u003c\/a\u003e suits small-volume labs running one formulation at a time. An \u003ca href=\"https:\/\/drugmachines.com\/products\/rcz-8a-intelligent-pharmaceutical-dissolution-tester\"\u003e8-channel tester (RCZ-8A)\u003c\/a\u003e accommodates USP \u0026lt;711\u0026gt; 6-vessel runs with 2 spares. A \u003ca href=\"https:\/\/drugmachines.com\/products\/rcz-12a-intelligent-pharmaceutical-dissolution-tester\"\u003e12-channel tester (RCZ-12A)\u003c\/a\u003e is ideal for high-throughput labs running two products simultaneously. As a rule: choose at minimum 8 channels for routine QC; upgrade to 12 if you have more than 3 active products in QC testing. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us for pricing.\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between syringe pump and peristaltic pump in automated sampling?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Syringe pumps (used in Huanghai RCZ-QY series) deliver precise, pulsation-free sample withdrawal—critical for viscous media or flow-sensitive APIs. Peristaltic pumps are lower cost but introduce pulsation artifacts that can affect UV absorbance readings in inline detection. For validated methods submitted to regulatory agencies, syringe-pump systems such as the \u003ca href=\"https:\/\/drugmachines.com\/products\/rcz-qy12-automatic-sampling-system\"\u003eRCZ-QY12\u003c\/a\u003e are preferred because they demonstrate superior reproducibility in audit-trail-backed data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the dissolution tester support FDA 21 CFR Part 11 compliance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Huanghai intelligent dissolution testers (RCZ-8N, RCZ-12A, RCZ-QY series) include audit trail functionality—timestamped records of all parameter changes and operator actions—meeting basic USP and ChP audit trail requirements. However, they are not certified as \u003cem\u003efully\u003c\/em\u003e 21 CFR Part 11 compliant because certain parameters remain modifiable for R\u0026amp;D flexibility. For FDA-regulated QC environments, pair the instrument with a validated LIMS or laboratory software stack to achieve full Part 11 compliance. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us\u003c\/a\u003e to discuss compliance configuration for your specific regulatory submission.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How often should dissolution media be degassed before testing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: USP \u0026lt;711\u0026gt; recommends degassing dissolution media immediately before use to remove dissolved oxygen that can cause bubble formation on tablet surfaces—leading to false-low dissolution results. Best practice: degas each media batch within 30 minutes of testing. The \u003ca href=\"https:\/\/drugmachines.com\/products\/htq-1a-vacuum-degasser\"\u003eHTQ-1A Vacuum Degasser\u003c\/a\u003e processes up to 25 liters in a single cycle using vacuum + UV sterilization, eliminating microbial contamination risk. For labs running 8–12 channel testers, a dedicated degasser prevents throughput bottlenecks between runs.\u003c\/p\u003e\n\n\u003c!-- CE Certification Block — do not remove --\u003e\n\u003cdiv style=\"margin:32px 0;padding:0;border:1px solid #c8daf5;border-radius:8px;overflow:hidden;font-family:sans-serif;\"\u003e\n  \u003cdiv style=\"background:#1a3a6b;padding:14px 20px;display:flex;align-items:center;gap:14px;\"\u003e\n    \u003cspan style=\"display:inline-block;color:#fff;font-size:24px;font-weight:900;letter-spacing:-1px;border:2px solid #fff;padding:2px 8px;border-radius:3px;font-family:serif;\"\u003eCE\u003c\/span\u003e\n    \u003cspan style=\"color:#fff;font-size:15px;font-weight:600;\"\u003eCE Certified — EU Regulatory Compliant\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background:#f5f8ff;padding:18px 20px;\"\u003e\n    \u003cp style=\"margin:0 0 12px 0;font-size:13.5px;color:#333;\"\u003eThis \u003cstrong\u003eDissolution Tester\u003c\/strong\u003e is CE certified under two EU directives:\u003c\/p\u003e\n    \u003cul style=\"margin:0 0 14px 0;padding-left:20px;font-size:13px;color:#444;line-height:1.7;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMachinery Directive 2006\/42\/EC\u003c\/strong\u003e — EN ISO 12100:2010 · EN 60204-1:2018 · EN 61010-1:2010+A1:2019\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eEMC Directive 2014\/30\/EU\u003c\/strong\u003e — EN IEC 61326-1:2021\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ca href=\"\/pages\/certifications\" style=\"color:#1a5fb4;font-size:13px;font-weight:600;text-decoration:none;\"\u003eView our CE certifications →\u003c\/a\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What pharmacopoeial standard governs dissolution testing?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Dissolution testing is governed by USP \u0026lt;711\u0026gt; (United States Pharmacopeia), ChP 0931 (Chinese Pharmacopoeia), and Ph.Eur. 2.9.3 (European Pharmacopoeia). All Huanghai RCZ-series dissolution testers are designed to comply with USP \u0026lt;711\u0026gt; paddle and basket methods, meeting the ±0.5 rpm speed tolerance and ±0.5°C temperature control requirements. For international market access, verify which pharmacopoeia your target regulatory body recognizes.\"}}, {\"@type\": \"Question\", \"name\": \"How many dissolution channels do I need for a QC lab?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Channel selection depends on your batch size and testing throughput. A 6-channel tester (RCZ-6N) suits small-volume labs running one formulation at a time. An 8-channel tester (RCZ-8A) accommodates USP \u0026lt;711\u0026gt; 6-vessel runs with 2 spares. A 12-channel tester (RCZ-12A) is ideal for high-throughput labs running two products simultaneously. As a rule: choose at minimum 8 channels for routine QC; upgrade to 12 if you have more than 3 active products in QC testing. Contact us for pricing.\"}}, {\"@type\": \"Question\", \"name\": \"What is the difference between syringe pump and peristaltic pump in automated sampling?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Syringe pumps (used in Huanghai RCZ-QY series) deliver precise, pulsation-free sample withdrawal—critical for viscous media or flow-sensitive APIs. Peristaltic pumps are lower cost but introduce pulsation artifacts that can affect UV absorbance readings in inline detection. For validated methods submitted to regulatory agencies, syringe-pump systems such as the RCZ-QY12 are preferred because they demonstrate superior reproducibility in audit-trail-backed data.\"}}, {\"@type\": \"Question\", \"name\": \"Does the dissolution tester support FDA 21 CFR Part 11 compliance?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Huanghai intelligent dissolution testers (RCZ-8N, RCZ-12A, RCZ-QY series) include audit trail functionality—timestamped records of all parameter changes and operator actions—meeting basic USP and ChP audit trail requirements. However, they are not certified as fully 21 CFR Part 11 compliant because certain parameters remain modifiable for R\u0026D flexibility. For FDA-regulated QC environments, pair the instrument with a validated LIMS or laboratory software stack to achieve full Part 11 compliance. Contact us to discuss compliance configuration for your specific regulatory submission.\"}}, {\"@type\": \"Question\", \"name\": \"How often should dissolution media be degassed before testing?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"USP \u0026lt;711\u0026gt; recommends degassing dissolution media immediately before use to remove dissolved oxygen that can cause bubble formation on tablet surfaces—leading to false-low dissolution results. Best practice: degas each media batch within 30 minutes of testing. The HTQ-1A Vacuum Degasser processes up to 25 liters in a single cycle using vacuum + UV sterilization, eliminating microbial contamination risk. For labs running 8–12 channel testers, a dedicated degasser prevents throughput bottlenecks between runs.\"}}]}\u003c\/script\u003e","brand":"Huanghai","offers":[{"title":"Default Title","offer_id":44205664600121,"sku":null,"price":16077.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/2495\/2889\/files\/high-capacity_dissolution_tester_front.jpg?v=1744267421"},{"product_id":"lb-3d-intelligent-disintegration-tester","title":"LB-3D Intelligent Disintegration Tester – High-Performance Pharmaceutical Testing Equipment","description":"\u003c!-- PRODUCT_ID: 7815949451321 --\u003e\n\u003c!-- TITLE: LB-3D Intelligent Disintegration Tester – High-Performance Pharmaceutical Testing Equipment --\u003e\n\u003ch2\u003e\n\u003ca name=\"_Toc187362377\"\u003e\u003c\/a\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan\u003eDisintegration Instruments\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eLB-3D Intelligent Disintegration Tester\u003c\/p\u003e\n\u003cdiv style=\"margin:1.5rem 0;padding:1rem 1.25rem;background:#f5f9ff;border-left:3px solid #0066cc;border-radius:3px;\"\u003e\n\u003cp style=\"margin:0;\"\u003ePharmaceutical quality control instrument designed to USP \/ FDA \/ GMP standards with comprehensive audit trail support for data integrity.\u003c\/p\u003e\n\u003cp style=\"margin:0.5rem 0 0 0;\"\u003e\u003cstrong\u003eVerify our credentials:\u003c\/strong\u003e \u003ca href=\"\/pages\/certifications\" style=\"color:#0066cc;\"\u003eCertifications\u003c\/a\u003e · \u003ca href=\"\/pages\/patents\" style=\"color:#0066cc;\"\u003ePatent Portfolio\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded-sm px-px py-[0.2rem]\"\u003eThe LB-3D Intelligent Disintegration Tester is a state-of-the-art \u003cstrong data-end=\"103\" data-start=\"66\"\u003epharmaceutical testing instrument\u003c\/strong\u003e designed for accurate assessment of tablet and capsule disintegration times.\u003c\/span\u003e \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded-sm px-px py-[0.2rem]\"\u003eCompliant with USP and other pharmacopoeia standards, this \u003cstrong data-end=\"84\" data-start=\"59\"\u003edisintegration tester\u003c\/strong\u003e features advanced automation and user-friendly controls, making it ideal for \u003cstrong data-end=\"209\" data-start=\"162\"\u003epharmaceutical quality control laboratories\u003c\/strong\u003e.\u003c\/span\u003e \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded-sm px-px py-[0.2rem]\"\u003eAs part of our comprehensive range of \u003cstrong data-end=\"76\" data-start=\"38\"\u003epharmaceutical testing instruments\u003c\/strong\u003e, the LB-3D ensures consistent and reproducible results, enhancing the efficiency of your \u003cstrong data-end=\"193\" data-start=\"166\"\u003epharmaceutical analysis\u003c\/strong\u003e processes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eDescription\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eThe LB series intelligent disintegration tester has been applied in the field of pharmaceutical analysis for over 40 years. Fully compliant with the latest \u003cb\u003eChinese Pharmacopoeia\u003c\/b\u003e standards, it is specifically designed to test the disintegration properties of solid dosage forms such as tablets, sugar-coated tablets, film-coated tablets, enteric-coated tablets, pills, and capsules under specified conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eProduct Features\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003e1. Advanced Data Management\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eBuilt-in three-tier user permissions, audit trails, and test record management.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eUSB connectivity supports direct test data export for reporting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eFrequently used data can be stored for quick and efficient use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003e2. High-Precision Temperature Control\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eReal-time temperature monitoring with dual-layer temperature protection and calibration functionality.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003ePreheating functionality allows users to schedule start times for heating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003e3. Optimized System Design\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eProfessional-grade circulation pipeline for efficient operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eFully compliant with pharmacopoeia standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003e4. Compliance and Certification\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eIncludes IQ\/OQ certification documentation for validation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpFirst\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eParameter\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eSpecification\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eModel\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eLB-3D\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eProduct Number\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e10107104\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eDisintegration Stations\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e3 stations (6 tubes)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eBasket Reciprocation Speed\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e25–35 strokes\/min\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eBasket Reciprocation Range\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e55±1.0mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eMinimum Basket Distance\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e25±1.0mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eSieve Aperture\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eStandard: 0.42mm, Optional: 0.71mm, 1.0mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eAdjustment Range\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eRoom temperature to 45.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eTemperature Uniformity\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e0.1°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eControl Precision\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e±0.3°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eCycle Limit\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u0026lt;100 cycles\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eCycle Time\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e≤999.9h\/59min59s\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003ePower Supply\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eAC220V±10%, 50Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cem\u003eLB-3D 3-station intelligent disintegration tester with audit-trail data management — Huanghai Pharmaceutical Instruments\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 style=\"margin-top: 24px\"\u003e📄 Download User Manual\u003c\/h3\u003e\n\u003cp\u003eYou can download the full user manual of the CJY-300E High-Speed Tablet Counting Machine below:\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 style=\"margin-top: 24px\"\u003e📄 Download User Manual\u003c\/h3\u003e\n\u003cp\u003eYou can download the full user manual of the LB-3D Intelligent Disintegration Tester below:\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/2495\/2889\/files\/LB-3D_EN_V2.2.pdf?v=1749948582\" style=\"color: #007ace;text-decoration: underline\" target=\"_blank\"\u003e 📥 Click here to download LB-3D User Manual (PDF) \u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"p1\" style=\"margin-top: 15px\"\u003e\n\u003cspan\u003e\n\u003cb\u003eNote:\u003c\/b\u003e Our lab instruments support basic audit trails strictly per USP\/ChP standards.\n  \u003c\/span\u003e\n\u003c\/p\u003e\n\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the USP standard for disintegration testing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Disintegration testing is governed by \u003cstrong\u003eUSP \u0026lt;701\u0026gt;\u003c\/strong\u003e (tablets and capsules) and \u003cstrong\u003eChP 0921\u003c\/strong\u003e. The test measures the time for a dosage form to break into particles small enough to pass through a specified mesh screen under simulated GI conditions. USP \u0026lt;701\u0026gt; requires testing in water or simulated gastric fluid at 37°C ± 2°C, with a reciprocating basket assembly. Huanghai LB-series testers are engineered to meet these parameters, with temperature-controlled water baths maintaining ±0.5°C accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the LB-2D and LB-3D disintegration testers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \u003ca href=\"https:\/\/drugmachines.com\/products\/lb-2d-disintegration-tester\"\u003eLB-2D\u003c\/a\u003e is a 2-station tester with a touchscreen interface—suited for small labs or single-product testing. The \u003ca href=\"https:\/\/drugmachines.com\/products\/lb-3d-intelligent-disintegration-tester\"\u003eLB-3D\u003c\/a\u003e adds a third station, enabling three simultaneous product tests, and includes an audit trail and data management system for GMP compliance. Choose LB-2D for budget-constrained or low-throughput environments; upgrade to LB-3D when your lab handles multiple formulations simultaneously or requires traceable electronic records for regulatory submissions. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us for pricing.\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does disintegration testing differ from dissolution testing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Disintegration measures whether a dosage form physically breaks apart within a specified time—it does not measure how much API is released. Dissolution (USP \u0026lt;711\u0026gt;) measures the rate and extent of API release into solution, which directly correlates with bioavailability. Disintegration is faster (typically 5–30 minutes) and is used as a routine in-process check; dissolution is the definitive QC test for bioavailability prediction. Many tablets that disintegrate quickly still have poor dissolution if the API is poorly soluble—disintegration alone is not sufficient for bioavailability assessment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the disintegration tester be used for suppositories or capsules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The LB-series testers support both tablet and capsule disintegration per USP \u0026lt;701\u0026gt;. For suppositories, the method differs—disintegration is measured using the melting time method (ChP 融变时限), which requires a different instrument: the \u003ca href=\"https:\/\/drugmachines.com\/products\/rby-n-intelligent-melting-time-tester\"\u003eRBY-N Melting Time Tester\u003c\/a\u003e. The RBY-N provides three parallel test units with adjustable rotation frequency, suitable for lipid-based suppository matrices. For complete lab capability, pair the LB-3D with the RBY-N to cover solid oral and rectal dosage forms.\u003c\/p\u003e\n\n\u003c!-- CE Certification Block — do not remove --\u003e\n\u003cdiv style=\"margin:32px 0;padding:0;border:1px solid #c8daf5;border-radius:8px;overflow:hidden;font-family:sans-serif;\"\u003e\n  \u003cdiv style=\"background:#1a3a6b;padding:14px 20px;display:flex;align-items:center;gap:14px;\"\u003e\n    \u003cspan style=\"display:inline-block;color:#fff;font-size:24px;font-weight:900;letter-spacing:-1px;border:2px solid #fff;padding:2px 8px;border-radius:3px;font-family:serif;\"\u003eCE\u003c\/span\u003e\n    \u003cspan style=\"color:#fff;font-size:15px;font-weight:600;\"\u003eCE Certified — EU Regulatory Compliant\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background:#f5f8ff;padding:18px 20px;\"\u003e\n    \u003cp style=\"margin:0 0 12px 0;font-size:13.5px;color:#333;\"\u003eThis \u003cstrong\u003eDisintegration Tester\u003c\/strong\u003e is CE certified under two EU directives:\u003c\/p\u003e\n    \u003cul style=\"margin:0 0 14px 0;padding-left:20px;font-size:13px;color:#444;line-height:1.7;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMachinery Directive 2006\/42\/EC\u003c\/strong\u003e — EN ISO 12100:2010 · EN 60204-1:2018 · EN 61010-1:2010+A1:2019\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eEMC Directive 2014\/30\/EU\u003c\/strong\u003e — EN IEC 61326-1:2021\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ca href=\"\/pages\/certifications\" style=\"color:#1a5fb4;font-size:13px;font-weight:600;text-decoration:none;\"\u003eView our CE certifications →\u003c\/a\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the USP standard for disintegration testing?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Disintegration testing is governed by USP \u0026lt;701\u0026gt; (tablets and capsules) and ChP 0921. The test measures the time for a dosage form to break into particles small enough to pass through a specified mesh screen under simulated GI conditions. USP \u0026lt;701\u0026gt; requires testing in water or simulated gastric fluid at 37°C ± 2°C, with a reciprocating basket assembly. Huanghai LB-series testers are engineered to meet these parameters, with temperature-controlled water baths maintaining ±0.5°C accuracy.\"}}, {\"@type\": \"Question\", \"name\": \"What is the difference between the LB-2D and LB-3D disintegration testers?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The LB-2D is a 2-station tester with a touchscreen interface—suited for small labs or single-product testing. The LB-3D adds a third station, enabling three simultaneous product tests, and includes an audit trail and data management system for GMP compliance. Choose LB-2D for budget-constrained or low-throughput environments; upgrade to LB-3D when your lab handles multiple formulations simultaneously or requires traceable electronic records for regulatory submissions. Contact us for pricing.\"}}, {\"@type\": \"Question\", \"name\": \"How does disintegration testing differ from dissolution testing?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Disintegration measures whether a dosage form physically breaks apart within a specified time—it does not measure how much API is released. Dissolution (USP \u0026lt;711\u0026gt;) measures the rate and extent of API release into solution, which directly correlates with bioavailability. Disintegration is faster (typically 5–30 minutes) and is used as a routine in-process check; dissolution is the definitive QC test for bioavailability prediction. Many tablets that disintegrate quickly still have poor dissolution if the API is poorly soluble—disintegration alone is not sufficient for bioavailability assessment.\"}}, {\"@type\": \"Question\", \"name\": \"Can the disintegration tester be used for suppositories or capsules?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. The LB-series testers support both tablet and capsule disintegration per USP \u0026lt;701\u0026gt;. For suppositories, the method differs—disintegration is measured using the melting time method (ChP 融变时限), which requires a different instrument: the RBY-N Melting Time Tester. The RBY-N provides three parallel test units with adjustable rotation frequency, suitable for lipid-based suppository matrices. For complete lab capability, pair the LB-3D with the RBY-N to cover solid oral and rectal dosage forms.\"}}]}\u003c\/script\u003e","brand":"Huanghai","offers":[{"title":"Default Title","offer_id":44205686882361,"sku":null,"price":3148.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/2495\/2889\/files\/LB-3D_disintegration_tester.jpg?v=1744271853"},{"product_id":"cjy-300e-tablet-friability-tester","title":"CJY-300E Tablet Friability Tester – Accurate Pharmaceutical Durability Testing Instrument","description":"\u003c!-- PRODUCT_ID: 7815957643321 --\u003e\n\u003c!-- TITLE: CJY-300E Tablet Friability Tester – Accurate Pharmaceutical Durability Testing Instrument --\u003e\n\u003ch2\u003e\n\u003ca name=\"_Toc187362377\"\u003e\u003c\/a\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan\u003eTablet Friability Instruments\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eCJY-300E Tablet Friability Tester\u003c\/p\u003e\n\u003cdiv style=\"margin:1.5rem 0;padding:1rem 1.25rem;background:#f5f9ff;border-left:3px solid #0066cc;border-radius:3px;\"\u003e\n\u003cp style=\"margin:0;\"\u003eTablet friability tester with adjustable speed and touchscreen interface. Visual observation workflow; results recorded manually.\u003c\/p\u003e\n\u003cp style=\"margin:0.5rem 0 0 0;\"\u003e\u003cstrong\u003eVerify our credentials:\u003c\/strong\u003e \u003ca href=\"\/pages\/certifications\" style=\"color:#0066cc;\"\u003eCertifications\u003c\/a\u003e · \u003ca href=\"\/pages\/patents\" style=\"color:#0066cc;\"\u003ePatent Portfolio\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded-sm px-px py-[0.2rem]\"\u003eThe CJY-300E Tablet Friability Tester is an advanced \u003cstrong data-end=\"90\" data-start=\"53\"\u003epharmaceutical testing instrument\u003c\/strong\u003e used to assess the friability of tablets.\u003c\/span\u003e \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded-sm px-px py-[0.2rem]\"\u003eFriability testing is vital to determine a tablet's resistance to abrasion and breakage during handling and transportation.\u003c\/span\u003e \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded-sm px-px py-[0.2rem]\"\u003eThe CJY-300E provides precise measurements, aiding \u003cstrong data-end=\"98\" data-start=\"51\"\u003epharmaceutical quality control laboratories\u003c\/strong\u003e in ensuring tablet durability and compliance with industry standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eDescription\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eThe CJY-300E Tablet Friability Tester complies with the standards of the \u003cb\u003eChinese Pharmacopoeia\u003c\/b\u003e and is designed for use in pharmaceutical manufacturing, research institutes, and hospitals. It evaluates the stability, abrasion resistance, and physical strength of tablets, making it an indispensable instrument for pharmaceutical quality testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eProduct Features\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003e1. User-Friendly Design\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eEquipped with a touch-screen human-machine interface for easy and intuitive operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eBilingual (Chinese and English) interface to meet diverse user needs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003e2. Precision and Reliability\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eAdjustable rotation speed and customizable rotation range for flexible testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eSupports both clockwise and counterclockwise rotation for comprehensive evaluation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003e3. Efficient and Safe Operation\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eOperates quietly with low power consumption for enhanced safety and efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eUtilizes DC12V power supply with universal voltage adapter, ensuring reliability and compatibility.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003e4. Compliance and Certification\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eIncludes IQ\/OQ certification documentation for validation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eParameter\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eSpecification\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpFirst\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eModel\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eCJY-300E\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eProduct Number\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e10102102\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eNumber of Drums\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e        \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e2 drums\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eDrum Dimensions\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e        \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eInner Diameter: 286mm, Depth: 39mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eDefault Rotation Speed\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e25 RPM\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eRotation Speed Range\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e20–100 RPM\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eDefault Rotation Count\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e100 cycles\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eRotation Count Range\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e1–1000 cycles\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eRotation Direction\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e        \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eClockwise\/Counterclockwise\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el   \u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eTiming Mode\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e       \u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eCount-up \/ count-down, preset up to 9h 59min 59sec\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003ePower Supply\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eDC12V, 3.0A\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cem\u003eCJY-300E tablet friability tester drum interior — Huanghai Pharmaceutical Instruments\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 style=\"margin-top: 24px\"\u003e📄 Download User Manual\u003c\/h3\u003e\n\u003cp\u003eYou can download the full user manual of the CJY-300E High-Speed Tablet Counting Machine below:\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/2495\/2889\/files\/CJY-300E_EN_V2.0.pdf?v=1749948310\" style=\"color: #007ace;text-decoration: underline\" target=\"_blank\"\u003e 📥 Click here to download CJY-300E User Manual (PDF) \u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"p1\" style=\"margin-top: 15px\"\u003e\n\u003cspan\u003e\n\u003cb\u003eNote:\u003c\/b\u003e Our lab instruments support basic audit trails strictly per USP\/ChP standards.\n  \u003c\/span\u003e\n\u003c\/p\u003e\n\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does USP specify for tablet friability testing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: \u003cstrong\u003eUSP \u0026lt;1216\u0026gt;\u003c\/strong\u003e specifies that uncoated tablets are tested at 25 rpm for 100 rotations (4 minutes). The mass loss must not exceed \u003cstrong\u003e1.0%\u003c\/strong\u003e for most tablet types. Coated tablets follow modified procedures depending on coating type. The \u003ca href=\"https:\/\/drugmachines.com\/products\/cjy-300e-tablet-friability-tester\"\u003eCJY-300E Friability Tester\u003c\/a\u003e operates at adjustable speeds to meet both standard USP and modified test protocols. Important: the CJY-300E uses visual observation—results are recorded manually. For labs requiring electronic data capture for audit trails, integrate with a connected balance and LIMS system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is an acceptable friability result for tablet release?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Per USP \u0026lt;1216\u0026gt;, a single test result of ≤1.0% mass loss is acceptable for most uncoated tablets. If one unit breaks or crumbles, re-test with the maximum value applying. For coated tablets, the specification is typically stricter: ≤0.5% is common for film-coated products, though the exact limit is formulation-specific. Friability failures often indicate problems with compression force, binder concentration, or moisture content—not just the test instrument.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does friability relate to tablet coating quality?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Friability measures mechanical robustness—tablets with high friability (\u0026gt;1%) will generate excessive dust and surface damage during coating pan tumbling, leading to uneven coat distribution and appearance defects. Pre-coating friability testing is therefore a critical in-process check. If core tablet friability exceeds 0.3–0.5%, reconsider the compression parameters (increase compaction force or binder level) before coating. This is especially important for enteric and modified-release coatings where surface imperfections compromise functional performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the friability tester be used for effervescent tablets?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, but with modified parameters. USP provides guidance for effervescent tablets: test 10 tablets at 100 rotations with a dehumidified drum to prevent premature reaction. The acceptable loss limit for effervescent formulations is typically ≤1.0% per USP \u0026lt;1216\u0026gt; Supplement. The \u003ca href=\"https:\/\/drugmachines.com\/products\/cjy-300e-tablet-friability-tester\"\u003eCJY-300E\u003c\/a\u003e supports variable speed (adjustable RPM) to accommodate these modified conditions. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us\u003c\/a\u003e to discuss drum configurations for specialized tablet forms.\u003c\/p\u003e\n\n\u003c!-- CE Certification Block — do not remove --\u003e\n\u003cdiv style=\"margin:32px 0;padding:0;border:1px solid #c8daf5;border-radius:8px;overflow:hidden;font-family:sans-serif;\"\u003e\n  \u003cdiv style=\"background:#1a3a6b;padding:14px 20px;display:flex;align-items:center;gap:14px;\"\u003e\n    \u003cspan style=\"display:inline-block;color:#fff;font-size:24px;font-weight:900;letter-spacing:-1px;border:2px solid #fff;padding:2px 8px;border-radius:3px;font-family:serif;\"\u003eCE\u003c\/span\u003e\n    \u003cspan style=\"color:#fff;font-size:15px;font-weight:600;\"\u003eCE Certified — EU Regulatory Compliant\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background:#f5f8ff;padding:18px 20px;\"\u003e\n    \u003cp style=\"margin:0 0 12px 0;font-size:13.5px;color:#333;\"\u003eThis \u003cstrong\u003eTablet Friability Tester\u003c\/strong\u003e is CE certified under two EU directives:\u003c\/p\u003e\n    \u003cul style=\"margin:0 0 14px 0;padding-left:20px;font-size:13px;color:#444;line-height:1.7;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMachinery Directive 2006\/42\/EC\u003c\/strong\u003e — EN ISO 12100:2010 · EN 60204-1:2018 · EN 61010-1:2010+A1:2019\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eEMC Directive 2014\/30\/EU\u003c\/strong\u003e — EN IEC 61326-1:2021\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ca href=\"\/pages\/certifications\" style=\"color:#1a5fb4;font-size:13px;font-weight:600;text-decoration:none;\"\u003eView our CE certifications →\u003c\/a\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What does USP specify for tablet friability testing?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"USP \u0026lt;1216\u0026gt; specifies that uncoated tablets are tested at 25 rpm for 100 rotations (4 minutes). The mass loss must not exceed 1.0% for most tablet types. Coated tablets follow modified procedures depending on coating type. The CJY-300E Friability Tester operates at adjustable speeds to meet both standard USP and modified test protocols. Important: the CJY-300E uses visual observation—results are recorded manually. For labs requiring electronic data capture for audit trails, integrate with a connected balance and LIMS system.\"}}, {\"@type\": \"Question\", \"name\": \"What is an acceptable friability result for tablet release?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Per USP \u0026lt;1216\u0026gt;, a single test result of ≤1.0% mass loss is acceptable for most uncoated tablets. If one unit breaks or crumbles, re-test with the maximum value applying. For coated tablets, the specification is typically stricter: ≤0.5% is common for film-coated products, though the exact limit is formulation-specific. Friability failures often indicate problems with compression force, binder concentration, or moisture content—not just the test instrument.\"}}, {\"@type\": \"Question\", \"name\": \"How does friability relate to tablet coating quality?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Friability measures mechanical robustness—tablets with high friability (\u003e1%) will generate excessive dust and surface damage during coating pan tumbling, leading to uneven coat distribution and appearance defects. Pre-coating friability testing is therefore a critical in-process check. If core tablet friability exceeds 0.3–0.5%, reconsider the compression parameters (increase compaction force or binder level) before coating. This is especially important for enteric and modified-release coatings where surface imperfections compromise functional performance.\"}}, {\"@type\": \"Question\", \"name\": \"Can the friability tester be used for effervescent tablets?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes, but with modified parameters. USP provides guidance for effervescent tablets: test 10 tablets at 100 rotations with a dehumidified drum to prevent premature reaction. The acceptable loss limit for effervescent formulations is typically ≤1.0% per USP \u0026lt;1216\u0026gt; Supplement. The CJY-300E supports variable speed (adjustable RPM) to accommodate these modified conditions. Contact us to discuss drum configurations for specialized tablet forms.\"}}]}\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"CJY-300E Tablet Friability Tester\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"Huanghai\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"Shanghai Huanghai Pharmaceutical Instruments Co., Ltd.\",\n    \"url\": \"https:\/\/drugmachines.com\"\n  },\n  \"category\": \"Tablet Friability Tester \/ Pharmaceutical Testing Instrument\",\n  \"description\": \"USP \u003c1216\u003e-compliant tablet friability tester. Single drum, 25 RPM, automatic weighing. GMP-grade pharmaceutical QC instrument for tablet quality control.\",\n  \"url\": \"https:\/\/drugmachines.com\/products\/cjy-300e-tablet-friability-tester\",\n  \"offers\": {\n    \"@type\": \"Offer\",\n    \"availability\": \"https:\/\/schema.org\/InStock\",\n    \"url\": \"https:\/\/drugmachines.com\/pages\/contact\",\n    \"priceCurrency\": \"USD\",\n    \"priceSpecification\": {\n      \"@type\": \"UnitPriceSpecification\",\n      \"description\": \"Contact for pricing and specifications\"\n    }\n  }\n}\n\u003c\/script\u003e\n\u003c!-- huanghai-product-schema-v1 --\u003e\n","brand":"Huanghai","offers":[{"title":"Default Title","offer_id":44205701333049,"sku":null,"price":1049.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/2495\/2889\/files\/tablet_friability_tester_20231127-1.15.jpg?v=1744296929"},{"product_id":"ryj-12b-pharmaceutical-transdermal-diffusion-tester","title":"RYJ-12B Transdermal Diffusion Tester – In-Vitro Skin Absorption Testing Instrument","description":"\u003c!-- PRODUCT_ID: 7815966031929 --\u003e\n\u003c!-- TITLE: RYJ-12B Transdermal Diffusion Tester – In-Vitro Skin Absorption Testing Instrument --\u003e\n\u003ch2\u003e\n\u003ca name=\"_Toc187362377\"\u003e\u003c\/a\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan\u003ePharmaceutical Transdermal Diffusion Instruments\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eRYJ-12B Pharmaceutical Transdermal Diffusion Tester\u003c\/p\u003e\n\u003cdiv style=\"margin:1.5rem 0;padding:1rem 1.25rem;background:#f5f9ff;border-left:3px solid #0066cc;border-radius:3px;\"\u003e\n\u003cp style=\"margin:0;\"\u003ePharmaceutical quality control instrument designed to USP \/ FDA \/ GMP standards with comprehensive audit trail support for data integrity.\u003c\/p\u003e\n\u003cp style=\"margin:0.5rem 0 0 0;\"\u003e\u003cstrong\u003eVerify our credentials:\u003c\/strong\u003e \u003ca href=\"\/pages\/certifications\" style=\"color:#0066cc;\"\u003eCertifications\u003c\/a\u003e · \u003ca href=\"\/pages\/patents\" style=\"color:#0066cc;\"\u003ePatent Portfolio\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp class=\"\" data-end=\"870\" data-start=\"705\"\u003eThe RYJ-12B Transdermal Diffusion Tester is a specialized \u003cstrong data-end=\"800\" data-start=\"763\"\u003epharmaceutical testing instrument\u003c\/strong\u003e designed to perform \u003cstrong data-end=\"867\" data-start=\"821\"\u003ein-vitro transdermal drug delivery testing\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"1060\" data-start=\"877\"\u003eUtilizing a precision-controlled system and Franz diffusion cells, this device simulates \u003cstrong data-end=\"985\" data-start=\"966\"\u003eskin absorption\u003c\/strong\u003e of topical or transdermal drug formulations under laboratory conditions.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"1252\" data-start=\"1067\"\u003eThe RYJ-12B is widely used in \u003cstrong data-end=\"1119\" data-start=\"1097\"\u003epharmaceutical R\u0026amp;D\u003c\/strong\u003e, formulation screening, and bioequivalence studies, ensuring reproducibility and compliance with international research standards.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"1445\" data-start=\"1259\"\u003eAs a core part of our \u003cstrong data-end=\"1319\" data-start=\"1281\"\u003epharmaceutical testing instruments\u003c\/strong\u003e lineup, the RYJ-12B helps pharmaceutical scientists evaluate drug release profiles and optimize transdermal delivery systems.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eDescription\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eThe RYJ-12B Pharmaceutical Transdermal Diffusion Tester is a collaborative product developed with the National Pharmaceutical Engineering Research Center (NPERC). It adopts an improved vertical Franz diffusion cell structure, where the film is clamped between the donor chamber lid (donor) and the receptor chamber (receptor). The inner surface of the film is immersed in a solution in the receptor chamber under conditions of constant temperature water bath circulation. With precise agitation, it ensures uniform distribution of the medium, simulating the drug’s transdermal penetration and release processes through biological membranes or artificial membranes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eProduct Features\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003e\u003cb\u003eInnovative Franz Cell Design:\u003c\/b\u003e Features 12 independently improved vertical Franz diffusion cells.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003e\u003cb\u003eMagnetic Stirring Mechanism:\u003c\/b\u003e Stable and uniform agitation ensures consistent dissolution concentration distribution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003e\u003cb\u003ePrecise Flow System:\u003c\/b\u003e Proprietary design guarantees uniformity in the diffusion medium circulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003e\u003cb\u003eTemperature Insulation:\u003c\/b\u003e Ensures stable minimum temperature deviation during tests.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003e\u003cb\u003eComprehensive Data Export:\u003c\/b\u003e Equipped with USB ports for exporting test records.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003e\u003cb\u003eUser-Friendly Interface:\u003c\/b\u003e Features a touch-screen interface supporting both English and Chinese operations for enhanced usability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpFirst\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eModel\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eRYJ-12B\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eProduct Code\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e10110100\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eNumber of Diffusion Cells\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e12 groups\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eVolume of Diffusion Cells\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e8mL\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eDiffusion Area\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eApprox. 2.2cm²\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eStirring Speed Range\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e100–800RPM\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eSpeed Stability Deviation\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e≤±1%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eTemperature Range\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eRoom temperature to 45°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eTemperature Resolution\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e0.1°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eTemperature Accuracy\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e≤±0.3°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eSample Collection Count\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e≤15 times\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eSample Collection Timing\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e≤9999 minutes\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003ePower Supply\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eAC220V±10%, 50Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\" style=\"margin-top: 15px\"\u003e\n\u003cspan\u003e\n\u003cb\u003eData Integrity:\u003c\/b\u003e Designed with features that support a 21 CFR Part 11 workflow — USB-based data export for traceable test records.\n  \u003c\/span\u003e\n\u003c\/p\u003e\n\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the regulatory pathway for transdermal patch approval?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: In the US, transdermal patches are regulated as drug products under FDA 21 CFR Parts 210\/211. New patches typically require an ANDA (for generic) or NDA (for novel formulations). Key dossier requirements include in vitro permeation testing (IVPT) data using Franz diffusion cells (USP \u0026lt;724\u0026gt;), comparative adhesion studies, and stability data at ICH conditions. The \u003ca href=\"https:\/\/drugmachines.com\/products\/ryj-12b-pharmaceutical-transdermal-diffusion-tester\"\u003eRYJ-12B Franz Cell Tester\u003c\/a\u003e generates the IVPT data required for regulatory submissions, using 12-cup vertical diffusion geometry conforming to FDA guidance. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us for pricing.\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is in vitro permeation testing (IVPT) and why is it required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: IVPT measures the rate and cumulative amount of API that permeates through a membrane (synthetic or excised skin) over time, using a Franz diffusion cell setup. For transdermal patches, IVPT data: (1) establishes in vitro release specifications for batch release; (2) supports bioequivalence claims for generic patches; (3) monitors manufacturing consistency batch-to-batch. FDA's 2022 draft guidance on topical drug bioavailability recommends IVPT as the primary method for many dermatological products. The \u003ca href=\"https:\/\/drugmachines.com\/products\/ryj-12b-pharmaceutical-transdermal-diffusion-tester\"\u003eRYJ-12B\u003c\/a\u003e supports 12 parallel diffusion cells with temperature-controlled receptor compartments (37°C ± 0.5°C).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why does the RYJ-12B use vertical Franz cells instead of horizontal diffusion cells?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Vertical Franz-type diffusion cells are the standard IVPT configuration for most transdermal and dermal formulations: the donor compartment holds the test formulation (patch, gel, ointment, cream) above the membrane, while the receptor compartment below collects permeated drug in a stirred buffer. The RYJ-12B is configured with 12 vertical wet-type cells for this standard workflow. For applications that also require horizontal (dry-type) diffusion testing — such as buccal or oral mucosal permeation studies — Huanghai's \u003ca href=\"https:\/\/drugmachines.com\/products\/tpy-2-pharmaceutical-transdermal-diffusion-tester\"\u003eTPY-2 dual-method diffusion tester\u003c\/a\u003e combines 12 vertical cells with 6 horizontal cells in a single instrument.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What receptor temperature should IVPT studies use, and how does the RYJ-12B control it?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Most IVPT protocols (following OECD 428 and FDA SUPAC-SS guidance) run the receptor compartment at 32°C ± 0.5°C to simulate normal skin surface temperature. The RYJ-12B's thermostatic water bath circulates across all 12 cells from room temperature up to 45°C, with ±0.3°C accuracy — comfortably within the typical 32°C target range needed for consistent, comparable permeation data across parallel cells. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us for method-specific parameter guidance.\u003c\/a\u003e\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the regulatory pathway for transdermal patch approval?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"In the US, transdermal patches are regulated as drug products under FDA 21 CFR Parts 210\/211. New patches typically require an ANDA (for generic) or NDA (for novel formulations). Key dossier requirements include in vitro permeation testing (IVPT) data using Franz diffusion cells (USP \u0026lt;724\u0026gt;), comparative adhesion studies, and stability data at ICH conditions. The RYJ-12B Franz Cell Tester generates the IVPT data required for regulatory submissions, using 12-cup vertical diffusion geometry conforming to FDA guidance. Contact us for pricing.\"}}, {\"@type\": \"Question\", \"name\": \"What is in vitro permeation testing (IVPT) and why is it required?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"IVPT measures the rate and cumulative amount of API that permeates through a membrane (synthetic or excised skin) over time, using a Franz diffusion cell setup. For transdermal patches, IVPT data: (1) establishes in vitro release specifications for batch release; (2) supports bioequivalence claims for generic patches; (3) monitors manufacturing consistency batch-to-batch. FDA's 2022 draft guidance on topical drug bioavailability recommends IVPT as the primary method for many dermatological products. The RYJ-12B supports 12 parallel diffusion cells with temperature-controlled receptor compartments (37°C ± 0.5°C).\"}}, {\"@type\": \"Question\", \"name\": \"Why does the RYJ-12B use vertical Franz cells instead of horizontal diffusion cells?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Vertical Franz-type diffusion cells are the standard IVPT configuration for most transdermal and dermal formulations: the donor compartment holds the test formulation above the membrane, while the receptor compartment below collects permeated drug in a stirred buffer. The RYJ-12B is configured with 12 vertical wet-type cells for this standard workflow. For applications that also require horizontal (dry-type) diffusion testing, Huanghai's TPY-2 dual-method diffusion tester combines 12 vertical cells with 6 horizontal cells in a single instrument.\"}}, {\"@type\": \"Question\", \"name\": \"What receptor temperature should IVPT studies use, and how does the RYJ-12B control it?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Most IVPT protocols (following OECD 428 and FDA SUPAC-SS guidance) run the receptor compartment at 32°C ± 0.5°C to simulate normal skin surface temperature. The RYJ-12B's thermostatic water bath circulates across all 12 cells from room temperature up to 45°C, with ±0.3°C accuracy, comfortably within the typical 32°C target range needed for consistent, comparable permeation data across parallel cells.\"}}]}\u003c\/script\u003e","brand":"Huanghai","offers":[{"title":"Default Title","offer_id":44205715980345,"sku":null,"price":3351.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/2495\/2889\/files\/ryj-12b-diffusion-tester-franz-cell.jpg?v=1744297959"},{"product_id":"mj150-odf-solvent-based-transdermal-patch-film-making-machine","title":"MJ150 ODF \u0026 Transdermal Patch Film Making Machine – Precision Pharmaceutical Film Production Equipment","description":"\u003c!-- TITLE: MJ150 ODF \u0026 Transdermal Patch Film Making Machine – Precision Pharmaceutical Film Production Equipment --\u003e\n\u003c!-- CRO v1 2026-05-13 — INI-005 M1 | LB-3D formula applied --\u003e\n\n\u003c!-- ABOVE-FOLD HERO CTA BLOCK --\u003e\n\u003cdiv style=\"margin:0 0 1.5rem 0;padding:1.25rem 1.5rem;background:#0055a5;border-radius:8px;text-align:center;\"\u003e\n  \u003cp style=\"margin:0 0 0.5rem 0;font-size:1.05rem;color:#fff;font-weight:600;\"\u003ePlanning an ODF production line or validating a new film formulation?\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 1rem 0;font-size:0.9rem;color:#cce0ff;\"\u003eGet technical specs, line configuration recommendations, and pricing — from our pharmaceutical engineering team.\u003c\/p\u003e\n  \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#0055a5;font-weight:700;font-size:0.95rem;padding:0.65rem 1.75rem;border-radius:6px;text-decoration:none;\"\u003eRequest Pricing \u0026amp; Line Configuration →\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- TRUST SIGNAL BLOCK --\u003e\n\n\n\u003c!-- PRODUCT INTRO --\u003e\n\u003ch2\u003eMJ150 ODF Film Coating Machine — MJ Pro Series\u003c\/h2\u003e\n\n\u003cp\u003eThe MJ150 is a continuous wet-film coating machine for oral dissolvable film (ODF) and solvent-based transdermal patch production. It delivers 20,000 films per hour at Gen I configuration, scalable to 120,000 films per hour in Gen III twin-tunnel configuration. Designed to support 21 CFR Part 11 compliance, with cGMP manufacturing standards throughout. Backed by 10-year equipment warranty.\u003c\/p\u003e\n\n\u003cp\u003eThe MJ150 uses a doctor-blade (scraper) casting method with patented hot-air gradient drying — producing a smooth, progressive temperature drop across the 6-meter drying tunnel, which protects heat-sensitive APIs and delivers superior film uniformity compared to conventional stepwise oven heating.\u003c\/p\u003e\n\n\u003c!-- GENERATION CAPACITY TABLE --\u003e\n\u003ch3\u003eProduction Capacity — Three Generations\u003c\/h3\u003e\n\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:0.92rem;margin-bottom:1rem;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background:#f0f4fa;\"\u003e\n      \u003cth style=\"padding:8px 12px;text-align:left;border:1px solid #d0d8e8;\"\u003eGeneration\u003c\/th\u003e\n      \u003cth style=\"padding:8px 12px;text-align:left;border:1px solid #d0d8e8;\"\u003eCasting Roll\u003c\/th\u003e\n      \u003cth style=\"padding:8px 12px;text-align:left;border:1px solid #d0d8e8;\"\u003eFull-Width Capacity\u003c\/th\u003e\n      \u003cth style=\"padding:8px 12px;text-align:left;border:1px solid #d0d8e8;\"\u003eStripe Capacity\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e\n\u003cstrong\u003eGen I\u003c\/strong\u003e (default factory config)\u003c\/td\u003e\n\u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e130 mm\u003c\/td\u003e\n\u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e\u003cstrong\u003e20,000 films\/hr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e3–4 stripes\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr style=\"background:#f9fbff;\"\u003e\n\u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e\u003cstrong\u003eGen II\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e400 mm\u003c\/td\u003e\n\u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e\u003cstrong\u003e60,000 films\/hr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e9–12 stripes\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e\n\u003cstrong\u003eGen III\u003c\/strong\u003e (Twin Tunnel)\u003c\/td\u003e\n\u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e400 mm × 2\u003c\/td\u003e\n\u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e\u003cstrong\u003e120,000 films\/hr\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e18–24 stripes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp style=\"font-size:0.85rem;color:#666;\"\u003eGeneration is selected at order time. Generation upgrades are not field-retrofit operations — the casting roll geometry and tunnel architecture differ between generations.\u003c\/p\u003e\n\n\u003c!-- KEY FEATURES --\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\n\u003ch4\u003e1. Patented Multi-Formula Stripe Coating\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eUp to 2 drug formulas applied simultaneously in one pass (patent CN117323228A)\u003c\/li\u003e\n  \u003cli\u003eCompetitors require manual multi-layer coating with drying between each layer — Huanghai eliminates this step\u003c\/li\u003e\n  \u003cli\u003eEnables fixed-dose combination ODF products on a single production run\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e2. Patented Hot-Air Gradient Drying\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eSmooth progressive temperature drop across 6-meter drying tunnel (patent CN201668734U)\u003c\/li\u003e\n  \u003cli\u003eDrying temperature: Room temperature to 120°C, fully configurable per zone\u003c\/li\u003e\n  \u003cli\u003eOptional far-infrared heating adds 20–30% drying efficiency\u003c\/li\u003e\n  \u003cli\u003eParticularly suited for heat-sensitive APIs — lower and more controllable drying temperature than hot-melt alternatives\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e3. Regulatory Compliance — cGMP and 21 CFR Part 11 Ready\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eDesigned to support 21 CFR Part 11 compliance: electronic audit trails, access control, operator records\u003c\/li\u003e\n  \u003cli\u003ecGMP-compliant construction and manufacturing standards throughout\u003c\/li\u003e\n  \u003cli\u003eSupports pharma-grade, supplement-grade, and food-grade ODF products\u003c\/li\u003e\n  \u003cli\u003eIQ\/OQ\/PQ documentation templates provided for facility qualification\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e4. Formulation Compatibility Across Scales\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eConsistent formulation performance from MJ150-Lab (pilot) to MJ150 Gen I \/ Gen II \/ Gen III (commercial scale)\u003c\/li\u003e\n  \u003cli\u003eNo formulation adjustment required when scaling — reduces validation burden and R\u0026amp;D cycle time\u003c\/li\u003e\n  \u003cli\u003eSame process platform from R\u0026amp;D to production: reduces technology transfer risk\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e5. Automation \u0026amp; Process Control\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eRunning speed: 0.2–5 m\/min (adjustable)\u003c\/li\u003e\n  \u003cli\u003eIntake and exhaust air velocity: 1–12 m\/s (configurable)\u003c\/li\u003e\n  \u003cli\u003eCompressed air pressure: 0.5–0.8 MPa\u003c\/li\u003e\n  \u003cli\u003eIntuitive control interface for real-time monitoring of drying temperature, air velocity, and coating speed\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n\u003ch3\u003eTechnical Specifications (Gen I Baseline)\u003c\/h3\u003e\n\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:0.92rem;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background:#f0f4fa;\"\u003e\n      \u003cth style=\"padding:8px 12px;text-align:left;border:1px solid #d0d8e8;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding:8px 12px;text-align:left;border:1px solid #d0d8e8;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:8px 12px;text-align:left;border:1px solid #d0d8e8;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding:8px 12px;text-align:left;border:1px solid #d0d8e8;\"\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e\u003cstrong\u003eRunning Speed\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e0.2–5 m\/min\u003c\/td\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e\u003cstrong\u003eDrying Temperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003eRoom Temp – 120°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9fbff;\"\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e\u003cstrong\u003eCoating Method\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003eScraper (Doctor-Blade)\u003c\/td\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e\u003cstrong\u003eCompressed Air Pressure\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e0.5–0.8 MPa\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e\u003cstrong\u003eCoating Width\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e130 mm (Gen I)\u003c\/td\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e\u003cstrong\u003eDrying Tunnel Length\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e6 m\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9fbff;\"\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e\u003cstrong\u003eCoating Thickness\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e0.1–2 mm\u003c\/td\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e3 × 220\/380V, 50Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e\u003cstrong\u003eAir Velocity (In\/Out)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e1–12 m\/s\u003c\/td\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e\u003cstrong\u003eMaximum Power\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e12 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background:#f9fbff;\"\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\"\u003e\u003cstrong\u003eEquipment Dimensions (L×W×H)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding:7px 12px;border:1px solid #e4eaf4;\" colspan=\"3\"\u003e9500 × 1400 × 2150 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003c!-- MID-PAGE CTA --\u003e\n\u003cdiv style=\"margin:2rem 0;padding:1.25rem 1.5rem;background:#f0f7ff;border:1px solid #b3d4ff;border-radius:8px;text-align:center;\"\u003e\n  \u003cp style=\"margin:0 0 0.75rem 0;font-size:0.95rem;color:#1a3a6b;font-weight:600;\"\u003eReady to size a production line for your target output?\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 0.75rem 0;font-size:0.88rem;color:#444;\"\u003eOur team will help you select the right generation configuration and pair it with cutting and packaging equipment.\u003c\/p\u003e\n  \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#0055a5;color:#fff;font-weight:700;font-size:0.9rem;padding:0.6rem 1.5rem;border-radius:6px;text-decoration:none;\"\u003eContact Huanghai Pharmaceutical Instruments →\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- WARRANTY \u0026 DELIVERY --\u003e\n\u003ch3\u003eWarranty \u0026amp; Delivery\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years for MJ150 ODF production equipment\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFactory Acceptance Test (FAT):\u003c\/strong\u003e 3 months (non-customized) \/ 4–6 months (customized configuration)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSite Acceptance Test (SAT):\u003c\/strong\u003e Within 1–2 months after FAT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRemote support:\u003c\/strong\u003e 10 hours per business day from international service team\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIQ\/OQ\/PQ documentation:\u003c\/strong\u003e Templates provided at no charge for facility qualification\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- VIDEO DEMO --\u003e\n\u003ch3\u003eProduct Demo\u003c\/h3\u003e\n\u003cp\u003eWatch the MJ150 in operation: \u003ca href=\"\/pages\/contact?subject=MJ150-video-demo\"\u003eRequest video demo from sales →\u003c\/a\u003e\u003c\/p\u003e\n\n\u003c!-- FAQ --\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the output of the MJ150 ODF film coating machine?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The MJ150 is available in three generations. Gen I (default factory demo configuration) produces \u003cstrong\u003e20,000 films per hour\u003c\/strong\u003e with a 130mm casting roll, suitable for commercial-scale ODF production. Gen II delivers 60,000 films per hour; Gen III (twin-tunnel) reaches 120,000 films per hour. Generation is selected at order time — these are not field-upgradeable configurations. \u003ca href=\"\/pages\/contact\"\u003eContact us\u003c\/a\u003e to confirm which generation matches your target output.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Can the MJ150 produce both ODF and transdermal patches?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes — the MJ150 platform supports both oral dissolvable film (ODF) and solvent-based transdermal patch production. However, switching between applications requires full replacement of dedicated component sets by Huanghai-qualified engineers (approximately 1–2 weeks). For overseas clients, this includes engineer travel and customs clearance for replacement parts. We recommend selecting your primary application at order time and treating the delivered line as dedicated to that application. If you genuinely need both, evaluate two separate lines. \u003ca href=\"\/pages\/contact\"\u003eContact us\u003c\/a\u003e to discuss your configuration.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does the MJ150 support 21 CFR Part 11 compliance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The MJ150 is designed to support 21 CFR Part 11 compliance, incorporating electronic audit trails, operator access control, and electronic record management. It meets cGMP manufacturing standards. Huanghai provides IQ\/OQ\/PQ documentation templates; on-site validation is conducted by the end user (or your local distributor as a value-added service) per standard industry practice. \u003ca href=\"\/pages\/contact\"\u003eContact us\u003c\/a\u003e for compliance documentation details.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the MJ150 and MJ150-Lab?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \u003ca href=\"\/products\/mj150-l-odf-film-coating-machine\"\u003eMJ150-Lab\u003c\/a\u003e is a pilot-scale version of the same platform, producing 8,000–10,000 films per hour — designed for R\u0026amp;D validation and small-batch production before scaling to commercial manufacturing. The same formulation developed on the MJ150-Lab transfers directly to the MJ150 Gen I \/ Gen II \/ Gen III without reformulation. Starting at pilot scale is a common path for new ODF product launches before committing to a full commercial line.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What patented technology is incorporated in the MJ150?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The MJ150 incorporates two key patented technologies: (1) Multi-formula stripe coating (patent CN117323228A) — enabling up to 2 drug formulas applied simultaneously in one pass, eliminating the multiple manual coating layers required by conventional systems. (2) patented hot-air gradient drying system (CN201668734U) — providing smooth progressive temperature drop across the drying tunnel for superior film uniformity and API protection. \u003ca href=\"\/pages\/patents\"\u003eView our patent portfolio.\u003c\/a\u003e\u003c\/p\u003e\n\n\u003c!-- BOTTOM CTA --\u003e\n\u003cdiv style=\"margin:2rem 0;padding:1.5rem;background:#0055a5;border-radius:8px;text-align:center;\"\u003e\n  \u003cp style=\"margin:0 0 0.5rem 0;font-size:1rem;color:#fff;font-weight:700;\"\u003eGet MJ150 specifications, line configuration, and pricing\u003c\/p\u003e\n  \u003cp style=\"margin:0 0 1rem 0;font-size:0.88rem;color:#cce0ff;\"\u003eResponse within 1 business day. Huanghai Pharmaceutical Instruments.\u003c\/p\u003e\n  \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#0055a5;font-weight:700;font-size:0.95rem;padding:0.65rem 1.75rem;border-radius:6px;text-decoration:none;\"\u003eRequest Pricing →\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- JSON-LD FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is the output of the MJ150 ODF film coating machine?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The MJ150 is available in three generations. Gen I produces 20,000 films per hour with a 130mm casting roll. Gen II delivers 60,000 films per hour; Gen III (twin-tunnel) reaches 120,000 films per hour. Generation is selected at order time. Contact us to confirm which generation matches your target output.\"}},{\"@type\":\"Question\",\"name\":\"Can the MJ150 produce both ODF and transdermal patches?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — the MJ150 platform supports both ODF and solvent-based transdermal patch production. Switching between applications requires full replacement of dedicated component sets by Huanghai-qualified engineers (approximately 1–2 weeks). We recommend selecting your primary application at order time.\"}},{\"@type\":\"Question\",\"name\":\"Does the MJ150 support 21 CFR Part 11 compliance?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The MJ150 is designed to support 21 CFR Part 11 compliance, incorporating electronic audit trails, operator access control, and electronic record management. It meets cGMP manufacturing standards. IQ\/OQ\/PQ documentation templates are provided; on-site validation is conducted by the end user.\"}},{\"@type\":\"Question\",\"name\":\"What is the difference between the MJ150 and MJ150-Lab?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The MJ150-Lab is a pilot-scale version producing 8,000–10,000 films per hour — for R\u0026D validation before scaling to commercial manufacturing. The same formulation transfers directly from MJ150-Lab to MJ150 Gen I\/II\/III without reformulation.\"}},{\"@type\":\"Question\",\"name\":\"What patented technology is incorporated in the MJ150?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The MJ150 incorporates multi-formula stripe coating (patent CN117323228A) — enabling up to 2 drug formulas applied simultaneously in one pass. It also uses patented hot-air gradient drying system (CN201668734U) for smooth progressive temperature control across the drying tunnel.\"}}]}\u003c\/script\u003e","brand":"Huanghai","offers":[{"title":"Default Title","offer_id":44205789184057,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/2495\/2889\/files\/mj150-machine-components.jpg?v=1744299869"},{"product_id":"mjf180-odf-film-cutting-and-packaging-machine","title":"MJ180 ODF Film Cutting and Packaging Machine – High-Speed Precision Cutting and Sealing Equipment","description":"\u003c!-- PRODUCT_ID: 7815995883577 --\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- TITLE: MJ180 ODF Film Cutting and Packaging Machine – High-Speed Precision Cutting and Sealing Equipment --\u003e\n\u003ch2\u003e\u003ca name=\"_Toc187362377\"\u003e\u003c\/a\u003e\u003c\/h2\u003e\n\u003cp style=\"padding: 15px; background-color: #f8f9fa; border-left: 4px solid #0056b3; font-style: italic; margin-bottom: 25px;\"\u003e\u003cstrong\u003eThe MJ180 ODF Film Cutting and Packaging Machine\u003c\/strong\u003e is developed by Huanghai Pharmaceutical Instruments — founded by the core team of China's National Pharmaceutical Engineering Research Center (NPERC) and backed by 97+ registered patents. Trusted by pharmaceutical manufacturers in 30+ countries for its capability to process 11,900 oral dissolving films (ODF) per hour.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e;\"\u003eCustomizable Film Cutting and Sealing System for ODF or Transdermal Patches\u003c\/span\u003e\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e \u003c\/p\u003e\n\u003cp\u003eMJ180 ODF Film Cutting and Packaging Machine\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #0e0e0e;\"\u003eThe MJ180 ODF Machine is specially designed for cutting and packaging oral dissolvable films. It supports fast, precise cutting with edge-sealing technology, perfect for ODF, OTF, CBD strips, and vitamin films.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003eThe MJ180 is a versatile cutting and packaging machine designed to handle Oral Dissolving Films (ODF) or solvent-based transdermal patches with precision and efficiency. This machine provides customizable solutions to meet the specific requirements of either ODF or transdermal patch production. Its advanced capabilities include precise cutting, aluminum-plastic composite sealing, and high-speed operation, making it an ideal choice for pharmaceutical manufacturers scaling up their production.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003eTwo Generations, Tailored to Your Production Needs\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003eThe MJ180 is now available in two distinct configurations to match your throughput and budget requirements:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- Gen 1 --\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e;\"\u003eGeneration 1 (Standard): Continuous Rotary Sealing\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-left: 15.75pt; margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e- \u003cb\u003eTechnology:\u003c\/b\u003e Rotary Heat Sealing Rollers\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-left: 15.75pt; margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e- \u003cb\u003eMechanism:\u003c\/b\u003e Uses a pair of continuously heated rotating rollers to seal pouch edges as the film passes through.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-left: 15.75pt; margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e- \u003cb\u003eBest For:\u003c\/b\u003e Entry-to-medium level production where cost-efficiency and stability are priorities.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-left: 15.75pt; margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e- \u003cb\u003eSpeed:\u003c\/b\u003e 40 cuts\/min\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003c!-- Gen 2 --\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e;\"\u003eGeneration 2 (High-Speed): On-Demand Heat Sealing\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-left: 15.75pt; margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e- \u003cb\u003eTechnology:\u003c\/b\u003e On-Demand Heat Sealing (Smart Intermittent)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-left: 15.75pt; margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e- \u003cb\u003eMechanism:\u003c\/b\u003e Advanced sealing jaws activate \u003cb\u003eonly\u003c\/b\u003e when precise sealing is required — synchronized perfectly with the cutting action.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-left: 15.75pt; margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e- \u003cb\u003eBenefits:\u003c\/b\u003e Precision, Energy Efficiency, and High Throughput.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-left: 15.75pt; margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e- \u003cb\u003eSpeed:\u003c\/b\u003e 100 cuts\/min\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003eThe MJ180 seamlessly integrates with other production models in the same series, ensuring a smooth transition from coating to packaging without the need for reformulating drug compounds. It is suitable for medium to large-scale production environments, ensuring reliability, accuracy, and compliance with international standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e;\"\u003eKey Features\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -15.75pt; line-height: normal; margin: 9.0pt 0cm 0cm 15.75pt;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003cspan\u003e     \u003c\/span\u003e•\u003cspan\u003e      \u003c\/span\u003e\u003cb\u003eSmart Sealing Options:\u003c\/b\u003e Choose between \u003cb\u003eRotary Heat Sealing\u003c\/b\u003e (Gen 1) for standard needs or \u003cb\u003eOn-Demand Heat Sealing\u003c\/b\u003e (Gen 2) for high-speed precision.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -15.75pt; line-height: normal; margin: 9.0pt 0cm 0cm 15.75pt;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003cspan\u003e     \u003c\/span\u003e1.\u003cspan\u003e      \u003c\/span\u003e\u003cb\u003eCustomizable Functionality:\u003c\/b\u003e Configurable for cutting and packaging Oral Dissolving Films (ODF) or transdermal patches, offering flexibility to cater to specific production needs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -15.75pt; line-height: normal; margin: 9.0pt 0cm 0cm 15.75pt;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003cspan\u003e     \u003c\/span\u003e2.\u003cspan\u003e      \u003c\/span\u003e\u003cb\u003eHigh-Precision Cutting:\u003c\/b\u003e Advanced cutting technology with an adjustable length range of 13–35 mm and an accuracy of ±0.1 mm ensures consistent results and minimal waste.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -15.75pt; line-height: normal; margin: 9.0pt 0cm 0cm 15.75pt;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003cspan\u003e     \u003c\/span\u003e3.\u003cspan\u003e      \u003c\/span\u003e\u003cb\u003eSeamless Integration:\u003c\/b\u003e Designed to integrate seamlessly with upstream coating machines, supporting efficient workflows without requiring drug formulation adjustments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -15.75pt; line-height: normal; margin: 9.0pt 0cm 0cm 15.75pt;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003cspan\u003e     \u003c\/span\u003e4.\u003cspan\u003e      \u003c\/span\u003e\u003cb\u003eAluminum-Plastic Sealing:\u003c\/b\u003e Equipped with a reliable heat-sealing mechanism for aluminum-plastic composite films, ensuring airtight and secure packaging.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -15.75pt; line-height: normal; margin: 9.0pt 0cm 0cm 15.75pt;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003cspan\u003e     \u003c\/span\u003e5.\u003cspan\u003e      \u003c\/span\u003e\u003cb\u003eEnhanced Production Efficiency:\u003c\/b\u003e Capable of operating at speeds of 0.5–3 m\/min, optimized for medium to large-scale manufacturing while maintaining product quality.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -15.75pt; line-height: normal; margin: 9.0pt 0cm 0cm 15.75pt;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003cspan\u003e     \u003c\/span\u003e6.\u003cspan\u003e      \u003c\/span\u003e\u003cb\u003eCompact and Durable Design:\u003c\/b\u003e A space-efficient footprint combined with robust construction ensures long-term durability and suitability for high-demand production environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -15.75pt; line-height: normal; margin: 9.0pt 0cm 0cm 15.75pt;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003cspan\u003e     \u003c\/span\u003e7.\u003cspan\u003e      \u003c\/span\u003e\u003cb\u003eUser-Friendly Interface:\u003c\/b\u003e Features an intuitive HMI touchscreen control for simplified operation, parameter adjustment, and real-time monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -15.75pt; line-height: normal; margin: 9.0pt 0cm 0cm 15.75pt;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003cspan\u003e     \u003c\/span\u003e8.\u003cspan\u003e      \u003c\/span\u003e\u003cb\u003eRegulatory Compliance:\u003c\/b\u003e Built to comply with cGMP and 21 CFR Part 11 standards, ensuring data integrity, traceability, and adherence to pharmaceutical manufacturing regulations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -15.75pt; line-height: normal; margin: 9.0pt 0cm 0cm 15.75pt;\"\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003cspan\u003e     \u003c\/span\u003e9.\u003cspan\u003e      \u003c\/span\u003e\u003cb\u003eEnergy Efficiency:\u003c\/b\u003e Powered by a high-performance system with a maximum power consumption of 10 kW, reducing operational costs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e;\"\u003eTechnical Parameters\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm; line-height: normal;\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpFirst\" style=\"text-indent: -22.0pt; line-height: normal; margin: 0cm 0cm 0cm 22.0pt;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"color: #0e0e0e;\"\u003eCutting Length\u003c\/span\u003e\u003cspan style=\"color: black;\"\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e13–35 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt; line-height: normal; margin: 0cm 0cm 0cm 22.0pt;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"color: #0e0e0e;\"\u003eCutting Accuracy\u003c\/span\u003e\u003cspan style=\"color: black;\"\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e±0.1 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt; line-height: normal; margin: 0cm 0cm 0cm 22.0pt;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"color: #0e0e0e;\"\u003eOperating Speed\u003c\/span\u003e\u003cspan style=\"color: black;\"\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e0.5–3 m\/min\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt; line-height: normal; margin: 0cm 0cm 0cm 22.0pt;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"color: #0e0e0e;\"\u003eHeat-Sealing Temp\u003c\/span\u003e\u003cspan style=\"color: black;\"\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e;\"\u003eRoom Temp–180°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt; line-height: normal; margin: 0cm 0cm 0cm 22.0pt;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"color: #0e0e0e;\"\u003eCompressed Air\u003c\/span\u003e\u003cspan style=\"color: black;\"\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e0.5–0.8 MPa\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt; line-height: normal; margin: 0cm 0cm 0cm 22.0pt;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"color: #0e0e0e;\"\u003ePower Supply\u003c\/span\u003e\u003cspan style=\"color: black;\"\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e3×220\/380V 50Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt; line-height: normal; margin: 0cm 0cm 0cm 22.0pt;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"color: #0e0e0e;\"\u003eMaximum Power\u003c\/span\u003e\u003cspan style=\"color: black;\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e10 kW\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"text-indent: -22.0pt; line-height: normal; margin: 0cm 0cm 0cm 22.0pt;\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cspan style=\"color: #0e0e0e;\"\u003eDimensions\u003c\/span\u003e\u003cspan style=\"color: black;\"\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e;\"\u003e5200 × 1450 × 2000 mm (L×W×H)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"text-indent: -22.0pt; line-height: normal; margin: 0cm 0cm 0cm 22.0pt;\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"text-indent: -22.0pt; line-height: normal; margin: 0cm 0cm 0cm 22.0pt;\"\u003e \u003c\/p\u003e\n\u003ch2\u003eFAQ - MJ180 ODF Machine\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What types of film can the MJ180 machine cut and package?\u003c\/strong\u003e\u003cbr\u003eA: It supports various oral dissolvable film materials like PVA, HPMC, and more.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this machine handle CBD or vitamin strips?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the MJ180 is suitable for packaging CBD, OTC, and nutraceutical film strips.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the cutting precision and speed?\u003c\/strong\u003e\u003cbr\u003eA: The machine achieves ±0.2mm precision with a working speed up to 10 meters per minute.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the machine support customized pouch sizes?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we support flexible pouch sizes and sealing configurations.\u003c\/p\u003e\n\u003cp class=\"p1\" style=\"margin-top: 15px;\"\u003e\u003cspan\u003e\u003cb\u003eHuanghai Exclusive Technology:\u003c\/b\u003e Features our patented hot-air drying system (Patent No. CN201668734U) ensuring uniform bottom-up heating and maximizing yield. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\" style=\"margin-top: 15px;\"\u003e\u003cspan\u003e\u003cb\u003eSafety Standard:\u003c\/b\u003e Engineered to meet \u003cb\u003eClass I Div 1 \/ ATEX\u003c\/b\u003e explosion-proof standards, ensuring safe handling of volatile transdermal solvents. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"geo-faq-section\" style=\"margin-top: 40px; border-top: 2px solid #eaeaea; padding-top: 20px;\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eQ: What is the processing throughput of the MJ180?\u003c\/h3\u003e\n\u003cp\u003eA: The MJ180 is an automatic, high-capacity system capable of cutting and packaging up to 11,900 oral dissolving films (ODF) per hour, making it ideal for large-scale commercial pharmaceutical production.\u003c\/p\u003e\n\u003ch3\u003eQ: What is the difference between the MJ180 and the EZ320?\u003c\/h3\u003e\n\u003cp\u003eA: The MJ180 belongs to our automated Pro Series, delivering synchronized continuous high-speed cutting and packaging (11,900 films\/hour). The EZ320 is our manual entry-level series, suited for lower volumes (9,000 films\/hour) or R\u0026amp;D scale operations.\u003c\/p\u003e\n\u003ch3\u003eQ: How is the MJ180 integrated into a complete ODF manufacturing line?\u003c\/h3\u003e\n\u003cp\u003eA: The MJ180 is engineered to seamlessly downstream from the MJ150 or MJ180 Coating Machines. Once the drug-loaded master roll is dried and wound on the coating machine, it is directly transferred to the MJ180 for precision slitting, cross-cutting, and individual pouch sealing within a GMP-compliant cleanroom environment.\u003c\/p\u003e\n\u003ch3\u003eQ: Does the equipment meet global pharmaceutical standards?\u003c\/h3\u003e\n\u003cp\u003eA: Yes. All Huanghai ODF processing equipment is designed strictly in accordance with cGMP and EU GMP Annex 11. System operations include access control, audit trails, and electronic batch recording capabilities aligned with FDA 21 CFR Part 11 requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between an ODF film and a transdermal patch?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Oral Dissolving Films (ODF) are placed on or under the tongue and dissolve within seconds to minutes, delivering APIs directly through the oral mucosa or via swallowing. Transdermal patches adhere to the skin and deliver APIs through the dermal layers into systemic circulation over hours to days. Despite different delivery routes, both are manufactured using similar solvent-cast film coating processes. Huanghai's \u003ca href=\"https:\/\/drugmachines.com\/products\/mj150-odf-solvent-based-transdermal-patch-film-making-machine\"\u003eMJ150 ODF machine\u003c\/a\u003e supports both applications on a single platform with approximately 2 working days of changeover time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What production output can I expect from a Huanghai ODF machine?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \u003ca href=\"https:\/\/drugmachines.com\/products\/mj150-odf-solvent-based-transdermal-patch-film-making-machine\"\u003eMJ150\u003c\/a\u003e produces \u003cstrong\u003e20,000 films\/hour\u003c\/strong\u003e at commercial scale. The \u003ca href=\"https:\/\/drugmachines.com\/products\/mj150-l-odf-film-coating-machine\"\u003eMJ150-L\u003c\/a\u003e targets R\u0026amp;D and pilot production at 8,000–10,000 films\/hour. For fully integrated lines, pair either machine with the \u003ca href=\"https:\/\/drugmachines.com\/products\/mjf180-odf-film-cutting-and-packaging-machine\"\u003eMJ180 automatic cutting and packaging system (11,900 films\/hr)\u003c\/a\u003e or the more affordable \u003ca href=\"https:\/\/drugmachines.com\/products\/ez320-odf-film-cutting-and-packaging-machine\"\u003eEZ320 (9,000 films\/hr)\u003c\/a\u003e. A complete MJ150 + MJ180 line can produce over 150 million finished pouches annually on a single-shift basis. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us for pricing and configuration details.\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What drying technology does Huanghai use for ODF production?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Huanghai uses patented gradient hot-air drying (\u003ca href=\"https:\/\/patents.google.com\/patent\/CN201668734U\/en\"\u003ePatent CN201668734U\u003c\/a\u003e), which applies a smooth progressive temperature drop rather than stepwise oven zones used by competitors. This results in more uniform film thickness, reduced edge curl, and better API distribution across the film web. An optional far-infrared heating module adds 20–30% drying efficiency for solvent-based formulations. This patented drying system is one of the key technical advantages that justifies Huanghai's position as the preferred ODF equipment supplier to Sinopharm, Shanghai Pharma, and Fosun Pharma.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the GMP requirements for ODF production equipment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: ODF manufacturing equipment must comply with \u003cstrong\u003ecGMP (21 CFR Parts 210\/211)\u003c\/strong\u003e for US market products, and equivalent standards (EU GMP Annex 1, ChGMP) for other markets. Key requirements: material contact surfaces must be 316L stainless steel or equivalent; CIP\/SIP capability or documented cleaning validation; data integrity controls meeting ALCOA+ principles (audit trails, access control). Huanghai ODF machines meet these standards—all product contact surfaces use pharmaceutical-grade materials, and the control system includes operator access logs and parameter change records. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eRequest our GMP compliance documentation.\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can Huanghai machines produce stripe-coated or multi-formula ODF films?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Huanghai holds a patent for multi-formula stripe coating (\u003ca href=\"https:\/\/patents.google.com\/patent\/CN117323228A\/en\"\u003ePatent CN117323228A\u003c\/a\u003e), enabling two different API formulations to be applied side-by-side in a single coating pass. This eliminates the need for multiple coating\/drying cycles when producing combination-drug ODF products. Competitors require manual multi-layer coating with drying intervals between each formula. This capability is particularly valuable for fixed-dose combination products (e.g., dual-API ODFs for cardiovascular or CNS indications) where coating efficiency directly impacts production economics.\u003c\/p\u003e\n\u003cp\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the difference between an ODF film and a transdermal patch?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Oral Dissolving Films (ODF) are placed on or under the tongue and dissolve within seconds to minutes, delivering APIs directly through the oral mucosa or via swallowing. Transdermal patches adhere to the skin and deliver APIs through the dermal layers into systemic circulation over hours to days. Despite different delivery routes, both are manufactured using similar solvent-cast film coating processes. Huanghai's MJ150 ODF machine supports both applications on a single platform with approximately 2 working days of changeover time.\"}}, {\"@type\": \"Question\", \"name\": \"What production output can I expect from a Huanghai ODF machine?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The MJ150 produces 20,000 films\/hour at commercial scale. The MJ150-L targets R\u0026D and pilot production at 8,000–10,000 films\/hour. For fully integrated lines, pair either machine with the MJ180 automatic cutting and packaging system (11,900 films\/hr) or the more affordable EZ320 (9,000 films\/hr). A complete MJ150 + MJ180 line can produce over 150 million finished pouches annually on a single-shift basis. Contact us for pricing and configuration details.\"}}, {\"@type\": \"Question\", \"name\": \"What drying technology does Huanghai use for ODF production?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Huanghai uses patented gradient hot-air drying (Patent CN201668734U), which applies a smooth progressive temperature drop rather than stepwise oven zones used by competitors. This results in more uniform film thickness, reduced edge curl, and better API distribution across the film web. An optional far-infrared heating module adds 20–30% drying efficiency for solvent-based formulations. This patented drying system is one of the key technical advantages that justifies Huanghai's position as the preferred ODF equipment supplier to Sinopharm, Shanghai Pharma, and Fosun Pharma.\"}}, {\"@type\": \"Question\", \"name\": \"What are the GMP requirements for ODF production equipment?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"ODF manufacturing equipment must comply with cGMP (21 CFR Parts 210\/211) for US market products, and equivalent standards (EU GMP Annex 1, ChGMP) for other markets. Key requirements: material contact surfaces must be 316L stainless steel or equivalent; CIP\/SIP capability or documented cleaning validation; data integrity controls meeting ALCOA+ principles (audit trails, access control). Huanghai ODF machines meet these standards—all product contact surfaces use pharmaceutical-grade materials, and the control system includes operator access logs and parameter change records. Request our GMP compliance documentation.\"}}, {\"@type\": \"Question\", \"name\": \"Can Huanghai machines produce stripe-coated or multi-formula ODF films?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. Huanghai holds a patent for multi-formula stripe coating (Patent CN117323228A), enabling two different API formulations to be applied side-by-side in a single coating pass. This eliminates the need for multiple coating\/drying cycles when producing combination-drug ODF products. Competitors require manual multi-layer coating with drying intervals between each formula. This capability is particularly valuable for fixed-dose combination products (e.g., dual-API ODFs for cardiovascular or CNS indications) where coating efficiency directly impacts production economics.\"}}]}\u003c\/script\u003e \u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"MJ180 ODF Film Cutting and Packaging Machine\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"Huanghai\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"Shanghai Huanghai Pharmaceutical Instruments Co., Ltd.\",\n    \"url\": \"https:\/\/drugmachines.com\"\n  },\n  \"category\": \"ODF Film Cutting and Packaging Machine\",\n  \"description\": \"High-speed ODF film cutting and sealing machine. Customizable cutting formats, hermetic sealing, GMP-certified design for pharmaceutical oral film packaging.\",\n  \"url\": \"https:\/\/drugmachines.com\/products\/mjf180-odf-film-cutting-and-packaging-machine\",\n  \"offers\": {\n    \"@type\": \"Offer\",\n    \"availability\": \"https:\/\/schema.org\/InStock\",\n    \"url\": \"https:\/\/drugmachines.com\/pages\/contact\",\n    \"priceCurrency\": \"USD\",\n    \"priceSpecification\": {\n      \"@type\": \"UnitPriceSpecification\",\n      \"description\": \"Contact for pricing and specifications\"\n    }\n  }\n}\n\u003c\/script\u003e\u003c\/p\u003e\n\u003c!-- huanghai-product-schema-v1 --\u003e","brand":"Huanghai","offers":[{"title":"Default Title","offer_id":44205821952057,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/2495\/2889\/files\/mjf180-odf-machine-front-view.jpg?v=1744254059"},{"product_id":"ez320-odf-film-cutting-and-packaging-machine","title":"EZ320 ODF Film Cutting and Packaging Machine","description":"\u003c!-- PRODUCT_ID: 8029772447801 --\u003e\n\u003c!-- TITLE: EZ320 ODF Film Cutting and Packaging Machine --\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eUniquely designed bag-making mechanism allows printing on both sides of each pouch with precise alignment.\u003c\/li\u003e\n\u003cli\u003eDirect membrane-to-pouch system ensures reliable transfer after slicing without intermediate transport issues.\u003c\/li\u003e\n\u003cli\u003eAdvanced continuous flat pressing heat-sealing mechanism with adjustable dwell time ensures excellent seal quality and broader material compatibility.\u003c\/li\u003e\n\u003cli\u003eOpen and visible mechanical design makes maintenance and troubleshooting easier.\u003c\/li\u003e\n\u003cli\u003eEquipped with PLC controller and proprietary software system. Servo-driven operations for feeding, film pulling, sealing, and cutting ensure precision and stability.\u003c\/li\u003e\n\u003cli\u003eIntegrated longitudinal film cutting system for inline slicing.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eWorkflow\u003c\/h2\u003e\n\u003cp\u003eFilm roll loading → Longitudinal slitting → Transverse cutting → Direct pouch insertion → Easy-tear pouch forming → Sealing → Final pouch cutting → Product output\u003c\/p\u003e\n\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilm size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 × 25 mm adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePouch size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 × 45 mm (adjustable by mold)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120–160 pouches\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFilm type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeat-sealable composite film (Max Ø320 mm, Max width 400 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220 V 50 Hz, Motor 4 kW + Heating 3 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥30 m³\/h at 0.6–0.8 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMachine weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e800 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (L×W×H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4000 × 1300 × 1600 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2200 × 1900 × 1800 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eConfiguration \u0026amp; Components\u003c\/h2\u003e\n\u003ch3\u003eA. Electrical Components\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eColor touchscreen (Xinje TG765G-UT)\u003c\/li\u003e\n\u003cli\u003eProgrammable logic controller (Xinje XD5-48T6)\u003c\/li\u003e\n\u003cli\u003e5 Servo motors (Xinje MS6S-80CS30B1-20P7)\u003c\/li\u003e\n\u003cli\u003e5 Servo drivers (Xinje DS5L-20P7-PTA)\u003c\/li\u003e\n\u003cli\u003eColor mark positioning system (GDJ612(N)W\/R, Shanghai Yatai)\u003c\/li\u003e\n\u003cli\u003eDischarge motor (41K25RGN-C, Oubang)\u003c\/li\u003e\n\u003cli\u003eOther electrical parts: relays, switches, buttons from Chint Electric\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eB. Mechanical Frame \u0026amp; Transmission Structure\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eFrame made of 40 × 40 × 2 mm 304 stainless steel square tubing.\u003c\/li\u003e\n\u003cli\u003eProtective cover made from 1.2 mm thick 304 stainless steel sheet.\u003c\/li\u003e\n\u003cli\u003eODF film traction roller made of 316L stainless steel.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between an ODF film and a transdermal patch?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Oral Dissolving Films (ODF) are placed on or under the tongue and dissolve within seconds to minutes, delivering APIs directly through the oral mucosa or via swallowing. Transdermal patches adhere to the skin and deliver APIs through the dermal layers into systemic circulation over hours to days. Despite different delivery routes, both are manufactured using similar solvent-cast film coating processes. Huanghai's \u003ca href=\"https:\/\/drugmachines.com\/products\/mj150-odf-solvent-based-transdermal-patch-film-making-machine\"\u003eMJ150 ODF machine\u003c\/a\u003e supports both applications on a single platform with approximately 2 working days of changeover time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What production output can I expect from a Huanghai ODF machine?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \u003ca href=\"https:\/\/drugmachines.com\/products\/mj150-odf-solvent-based-transdermal-patch-film-making-machine\"\u003eMJ150\u003c\/a\u003e produces \u003cstrong\u003e20,000 films\/hour\u003c\/strong\u003e at commercial scale. The \u003ca href=\"https:\/\/drugmachines.com\/products\/mj150-l-odf-film-coating-machine\"\u003eMJ150-L\u003c\/a\u003e targets R\u0026amp;D and pilot production at 8,000–10,000 films\/hour. For fully integrated lines, pair either machine with the \u003ca href=\"https:\/\/drugmachines.com\/products\/mjf180-odf-film-cutting-and-packaging-machine\"\u003eMJ180 automatic cutting and packaging system (11,900 films\/hr)\u003c\/a\u003e or the more affordable \u003ca href=\"https:\/\/drugmachines.com\/products\/ez320-odf-film-cutting-and-packaging-machine\"\u003eEZ320 (9,000 films\/hr)\u003c\/a\u003e. A complete MJ150 + MJ180 line can produce over 150 million finished pouches annually on a single-shift basis. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us for pricing and configuration details.\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What drying technology does Huanghai use for ODF production?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Huanghai uses patented gradient hot-air drying (\u003ca href=\"https:\/\/patents.google.com\/patent\/CN201668734U\/en\"\u003ePatent CN201668734U\u003c\/a\u003e), which applies a smooth progressive temperature drop rather than stepwise oven zones used by competitors. This results in more uniform film thickness, reduced edge curl, and better API distribution across the film web. An optional far-infrared heating module adds 20–30% drying efficiency for solvent-based formulations. This patented drying system is one of the key technical advantages that justifies Huanghai's position as the preferred ODF equipment supplier to Sinopharm, Shanghai Pharma, and Fosun Pharma.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the GMP requirements for ODF production equipment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: ODF manufacturing equipment must comply with \u003cstrong\u003ecGMP (21 CFR Parts 210\/211)\u003c\/strong\u003e for US market products, and equivalent standards (EU GMP Annex 1, ChGMP) for other markets. Key requirements: material contact surfaces must be 316L stainless steel or equivalent; CIP\/SIP capability or documented cleaning validation; data integrity controls meeting ALCOA+ principles (audit trails, access control). Huanghai ODF machines meet these standards—all product contact surfaces use pharmaceutical-grade materials, and the control system includes operator access logs and parameter change records. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eRequest our GMP compliance documentation.\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can Huanghai machines produce stripe-coated or multi-formula ODF films?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Huanghai holds a patent for multi-formula stripe coating (\u003ca href=\"https:\/\/patents.google.com\/patent\/CN117323228A\/en\"\u003ePatent CN117323228A\u003c\/a\u003e), enabling two different API formulations to be applied side-by-side in a single coating pass. This eliminates the need for multiple coating\/drying cycles when producing combination-drug ODF products. Competitors require manual multi-layer coating with drying intervals between each formula. This capability is particularly valuable for fixed-dose combination products (e.g., dual-API ODFs for cardiovascular or CNS indications) where coating efficiency directly impacts production economics.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the difference between an ODF film and a transdermal patch?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Oral Dissolving Films (ODF) are placed on or under the tongue and dissolve within seconds to minutes, delivering APIs directly through the oral mucosa or via swallowing. Transdermal patches adhere to the skin and deliver APIs through the dermal layers into systemic circulation over hours to days. Despite different delivery routes, both are manufactured using similar solvent-cast film coating processes. Huanghai's MJ150 ODF machine supports both applications on a single platform with approximately 2 working days of changeover time.\"}}, {\"@type\": \"Question\", \"name\": \"What production output can I expect from a Huanghai ODF machine?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The MJ150 produces 20,000 films\/hour at commercial scale. The MJ150-L targets R\u0026D and pilot production at 8,000–10,000 films\/hour. For fully integrated lines, pair either machine with the MJ180 automatic cutting and packaging system (11,900 films\/hr) or the more affordable EZ320 (9,000 films\/hr). A complete MJ150 + MJ180 line can produce over 150 million finished pouches annually on a single-shift basis. Contact us for pricing and configuration details.\"}}, {\"@type\": \"Question\", \"name\": \"What drying technology does Huanghai use for ODF production?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Huanghai uses patented gradient hot-air drying (Patent CN201668734U), which applies a smooth progressive temperature drop rather than stepwise oven zones used by competitors. This results in more uniform film thickness, reduced edge curl, and better API distribution across the film web. An optional far-infrared heating module adds 20–30% drying efficiency for solvent-based formulations. This patented drying system is one of the key technical advantages that justifies Huanghai's position as the preferred ODF equipment supplier to Sinopharm, Shanghai Pharma, and Fosun Pharma.\"}}, {\"@type\": \"Question\", \"name\": \"What are the GMP requirements for ODF production equipment?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"ODF manufacturing equipment must comply with cGMP (21 CFR Parts 210\/211) for US market products, and equivalent standards (EU GMP Annex 1, ChGMP) for other markets. Key requirements: material contact surfaces must be 316L stainless steel or equivalent; CIP\/SIP capability or documented cleaning validation; data integrity controls meeting ALCOA+ principles (audit trails, access control). Huanghai ODF machines meet these standards—all product contact surfaces use pharmaceutical-grade materials, and the control system includes operator access logs and parameter change records. Request our GMP compliance documentation.\"}}, {\"@type\": \"Question\", \"name\": \"Can Huanghai machines produce stripe-coated or multi-formula ODF films?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. Huanghai holds a patent for multi-formula stripe coating (Patent CN117323228A), enabling two different API formulations to be applied side-by-side in a single coating pass. This eliminates the need for multiple coating\/drying cycles when producing combination-drug ODF products. Competitors require manual multi-layer coating with drying intervals between each formula. This capability is particularly valuable for fixed-dose combination products (e.g., dual-API ODFs for cardiovascular or CNS indications) where coating efficiency directly impacts production economics.\"}}]}\u003c\/script\u003e","brand":"Huanghai","offers":[{"title":"Default Title","offer_id":44900718215225,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/2495\/2889\/files\/EZ320_d339fd94-2c49-4776-89b7-511f23843b9e.png?v=1758691299"}],"url":"https:\/\/79dv0w-hi.myshopify.com\/collections\/homepage-collection.oembed","provider":"Huanghai Pharmaceutical Instruments","version":"1.0","type":"link"}