{"title":"HPLC Systems","description":"\u003ch2\u003eHPLC Systems\u003c\/h2\u003e\n\u003cp\u003eHigh-performance liquid chromatography (HPLC) is a core method for pharmaceutical assay, impurity profiling, and quality control analysis. Our \u003cstrong\u003eLC210 and EasySep-5010 HPLC Systems\u003c\/strong\u003e cover both single\/dual-pump isocratic and gradient configurations and a modular quaternary-pump platform for this workflow.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLC210: single-pump isocratic or dual-pump binary gradient delivery, UV detector, PID-controlled column thermostat, 7\" touchscreen workstation\u003c\/li\u003e\n\u003cli\u003eEasySep-5010: modular quaternary pump, UV\/DAD detection, autosampler, and chromatography data system with audit-trail logging\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePharmaceutical assay and impurity profiling\u003c\/li\u003e\n\u003cli\u003eQuality control laboratory analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's the difference between EasySep-5010 and LC210?\u003c\/strong\u003e\u003cbr\u003e\nEasySep-5010 is a modular quaternary-pump system (4-channel simultaneous mobile-phase delivery) with a dual-lamp UV detector plus a photodiode-array (DAD) detector. LC210 is available as Single Pump (isocratic) or Dual Pump (binary gradient) variants of the same product, with a UV detector (190-700nm).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat detector types are available?\u003c\/strong\u003e\u003cbr\u003e\nEasySep-5010 uses a dual-lamp UV detector and a 1024-element photodiode array DAD. LC210 uses a UV detector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo these systems support audit-trail data management?\u003c\/strong\u003e\u003cbr\u003e\nEasySep-5010's chromatography data system supports multi-user access, audit trail, and electronic signature. LC210's touchscreen workstation has an optional audit-trail add-on.\u003c\/p\u003e\n\u003cp\u003eExplore the full lineup below to find the right solution for your lab. For quotation or technical support, \u003ca href=\"\/pages\/contact\"\u003econtact our team\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"easysep-5010-hplc-system","title":"EasySep-5010 HPLC System – Modular High-Performance Liquid Chromatography Platform","description":"\u003c!-- PRODUCT_ID: 8324431708217 --\u003e\n\u003c!-- TITLE: EasySep-5010 HPLC System – Modular High-Performance Liquid Chromatography Platform --\u003e\n\u003c!-- Drafted 2026-07-03 from Vault\/01-Knowledge\/EasySep®-5010 HPLC\/ source material. EN only. Revised 2026-07-04 per Mike: removed all blue CTA boxes, table converted to plain text — see §6.2. --\u003e\n\n\u003c!-- PRODUCT INTRO --\u003e\n\u003ch2\u003eEasySep-5010 HPLC System — Modular Platform for Pharmaceutical Analysis\u003c\/h2\u003e\n\n\u003cp\u003eThe EasySep-5010 HPLC System is a modular, fully automated quaternary UHPLC platform. Its four-channel pump can simultaneously deliver up to four mobile phases, paired with an upgraded injection system, separation system, and detection system, and a chromatography workstation with a built-in database — delivering reliable test data and improving laboratory analysis efficiency.\u003c\/p\u003e\n\n\u003cp\u003eThe system's four pump channels can be freely combined to meet different flow and method requirements. The chromatography workstation controls all modules together and supports fully automated, long-duration unattended sequence runs — improving analytical throughput while keeping operation simple and maintenance cost low.\u003c\/p\u003e\n\n\u003c!-- KEY DIFFERENTIATORS --\u003e\n\u003ch3\u003eSystem Modules\u003c\/h3\u003e\n\n\u003ch4\u003e1. Quaternary Solvent Delivery Pump\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eFour-channel quaternary pump design delivers up to four mobile phases simultaneously for flexible gradient method development\u003c\/li\u003e\n  \u003cli\u003eBuilt-in four-channel online degasser automatically removes dissolved gas from mobile phases, preventing bubble formation\u003c\/li\u003e\n  \u003cli\u003eBuilt-in automated flush\/cleaning function with configurable wash programs for unattended in-line seal cleaning\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e2. Column Thermostat\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eSoftware-controlled temperature regulation with real-time temperature display\u003c\/li\u003e\n  \u003cli\u003eHolds multiple chromatography columns simultaneously, with software-configurable automatic column switching\u003c\/li\u003e\n  \u003cli\u003eWide control range with fast ramp-up to reduce equilibration time between runs\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e3. UV\/Vis Detector\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eDual optical path design enables simultaneous dual-wavelength detection, plus time-programmed wavelength and static wavelength-scan modes\u003c\/li\u003e\n  \u003cli\u003eAutomatically logs fault codes, lamp usage hours, and component-replacement history, with power-on self-test\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e4. DAD — Diode Array Detector\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eDiode-array detection technology enables simultaneous multi-wavelength monitoring, full 3D spectral acquisition, and peak-purity calculation\u003c\/li\u003e\n  \u003cli\u003eDigital and analog signal outputs for compatibility with third-party chromatography data software\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e5. Autosampler\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eFully software-controlled autosampler enables unattended sample analysis, reducing operator time\u003c\/li\u003e\n  \u003cli\u003eFlexible injection modes with selectable sample-loop volumes to match different injection-volume requirements\u003c\/li\u003e\n  \u003cli\u003eMultiple wash\/rinse modes minimize cross-contamination between injections\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003e6. Chromatography Data System\u003c\/h4\u003e\n\u003cul\u003e\n  \u003cli\u003eStrict user permission management and audit trail, with a built-in database supporting compliance with relevant regulatory requirements\u003c\/li\u003e\n  \u003cli\u003eExtensible instrument control — supports simultaneous control of up to four systems through one graphical interface\u003c\/li\u003e\n  \u003cli\u003eCentralized workstation controls all modules (pump, detectors, column oven, autosampler), monitors operating parameters and status, and manages data acquisition, chromatogram analysis, and report printing\u003c\/li\u003e\n  \u003cli\u003eSupports sequence\/batch processing and event-triggered automation for long, unattended analytical runs\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003c!-- SYSTEM CONFIGURATION — plain text, no table markup --\u003e\n\u003ch3\u003eSystem Configuration\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQuaternary Pump:\u003c\/strong\u003e 4-channel solvent delivery, built-in online degasser, automated seal-wash cleaning\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColumn Thermostat:\u003c\/strong\u003e Software-controlled temperature regulation, multi-column capacity with automatic switching\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUV\/Vis Detector:\u003c\/strong\u003e Dual optical path, simultaneous dual-wavelength detection\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDiode Array Detector (DAD):\u003c\/strong\u003e Multi-wavelength simultaneous detection, 3D spectral acquisition, peak-purity calculation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutosampler:\u003c\/strong\u003e Fully automated injection, multiple injection modes and wash cycles\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChromatography Data System:\u003c\/strong\u003e Multi-user permissions, audit trail, simultaneous control of up to 4 instruments\u003c\/p\u003e\n\n\u003c!-- FAQ --\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Is the EasySep-5010 HPLC System modular?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. The EasySep-5010 integrates a quaternary solvent delivery pump, column thermostat, UV\/Vis detector, diode array detector (DAD), autosampler, and chromatography data system as independent modules. The pump's four channels can be freely combined to meet different flow and method requirements. Contact us to discuss the module configuration for your lab.\"}}, {\"@type\": \"Question\", \"name\": \"What's the difference between the UV\/Vis detector and the DAD detector?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The UV\/Vis detector uses a dual optical path for simultaneous dual-wavelength detection, with time-programmed wavelength and static wavelength-scan modes. The DAD (diode array detector) uses diode-array detection technology for simultaneous multi-wavelength monitoring, full 3D spectral acquisition, and peak-purity calculation. Contact us to discuss which configuration fits your method.\"}}, {\"@type\": \"Question\", \"name\": \"Does the EasySep-5010 support data integrity requirements for GMP labs?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. The chromatography data system provides strict user permission management and an audit trail, with a built-in database supporting compliance with relevant regulatory and data-integrity requirements. Contact us to discuss documentation for your regulatory environment.\"}}]}\u003c\/script\u003e\n\n\n\u003cp\u003e\u003cstrong\u003eQ: Is the EasySep-5010 HPLC System modular?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The EasySep-5010 integrates a quaternary solvent delivery pump, column thermostat, UV\/Vis detector, diode array detector (DAD), autosampler, and chromatography data system as independent modules. The pump's four channels can be freely combined to meet different flow and method requirements. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us\u003c\/a\u003e to discuss the module configuration for your lab.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What's the difference between the UV\/Vis detector and the DAD detector?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The UV\/Vis detector uses a dual optical path for simultaneous dual-wavelength detection, with time-programmed wavelength and static wavelength-scan modes. The DAD (diode array detector) uses diode-array detection technology for simultaneous multi-wavelength monitoring, full 3D spectral acquisition, and peak-purity calculation. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us\u003c\/a\u003e to discuss which configuration fits your method.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does the EasySep-5010 support data integrity requirements for GMP labs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The chromatography data system provides strict user permission management and an audit trail, with a built-in database supporting compliance with relevant regulatory and data-integrity requirements. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us\u003c\/a\u003e to discuss documentation for your regulatory environment.\u003c\/p\u003e\n","brand":"Huanghai","offers":[{"title":"Default Title","offer_id":46151208468537,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/2495\/2889\/files\/EasySep-5010_HPLC_system_High_RES.png?v=1783088856"},{"product_id":"lc210-hplc-system","title":"LC210 HPLC System — High-Performance Liquid Chromatography Platform","description":"\u003c!-- TITLE: LC210 HPLC System — High-Performance Liquid Chromatography Platform --\u003e\n\u003c!-- Drafted 2026-07-21 from Vault\/01-Knowledge\/HPLC\/LC210_HPLC_Brochure_Extract.md (source: 仪电分析-中文样本-整本2501.pdf P56). EN only, DRAFT. --\u003e\n\n\u003ch2\u003eLC210 HPLC System — High-Performance Liquid Chromatography Platform\u003c\/h2\u003e\n\n\u003cp\u003eThe LC210 HPLC System is a high-performance liquid chromatography platform built around a stable reciprocating series-flow constant-flow pump, a PID-controlled column thermostat, and a UV detector, operated through a 7\" color touchscreen with built-in workstation software. Available in a single-pump configuration for high-precision isocratic delivery, or a dual-pump configuration that adds binary high-pressure gradient elution with in-line mixing for uniform mobile-phase blending.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-sensitivity detector with a fluid-dynamics-optimized heat-dissipation channel and a thermally isolated, insulated design that suppresses the effect of ambient temperature swings, plus strong electromagnetic shielding\u003c\/li\u003e\n  \u003cli\u003eHighly integrated microprocessor and multi-bus architecture, low-drift low-noise high-sensitivity preamplifier, 24-bit precision A\/D conversion\u003c\/li\u003e\n  \u003cli\u003eStable-flow reciprocating series constant-flow pump rated for high pressure, easy to maintain; a high-performance buffer smooths pulsation for precise, stable flow — supports high-precision isocratic delivery, or binary high-pressure gradient elution with a mixer for uniform blending of different mobile phases\u003c\/li\u003e\n  \u003cli\u003eKey wear parts (e.g. plunger rod) support in-line cleaning to extend seal life; process-control monitoring flags blockages and leaks\u003c\/li\u003e\n  \u003cli\u003e7\" color touchscreen with built-in workstation software (audit-trail capability available as an add-on), bidirectional operation\u003c\/li\u003e\n  \u003cli\u003ePrecision-machined on CNC equipment for consistent build quality, with imported core components and accessories\u003c\/li\u003e\n  \u003cli\u003eLong-life imported deuterium lamp with a dedicated lamp power supply; modular flow-cell design for easy disassembly and cleaning; manual or automatic injector available\u003c\/li\u003e\n  \u003cli\u003eTime-programmed wavelength detection\u003c\/li\u003e\n  \u003cli\u003ePID auto-tuning algorithm for precise column-oven temperature control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSystem Configuration\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eColumn Thermostat:\u003c\/strong\u003e Control accuracy ±1°C; range ambient+10°C to 80°C (1°C increments); temperature stability ≤0.2°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Pressure Pump:\u003c\/strong\u003e Flow-rate setting range 0.001–9.999 mL\/min; flow stability ≤0.3%; maximum output pressure 45 MPa\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUV Detector:\u003c\/strong\u003e Wavelength range 190–700 nm; wavelength accuracy ±1 nm; wavelength repeatability ≤0.2 nm\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBaseline Noise:\u003c\/strong\u003e ≤5×10⁻⁶ AU (254 nm, empty cell); ≤9×10⁻⁶ AU (254 nm, methanol mobile phase)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBaseline Drift:\u003c\/strong\u003e ≤5×10⁻⁵ AU\/h (254 nm, empty cell); ≤1×10⁻⁴ AU\/h (254 nm, methanol mobile phase)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Detectable Concentration:\u003c\/strong\u003e ≤5×10⁻⁹ g\/mL (sample: naphthalene; carrier: methanol; 254 nm)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRepeatability:\u003c\/strong\u003e Qualitative ≤0.3% (manual injection); Quantitative ≤0.9% (manual injection)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e 220V±22V, 50Hz±0.5Hz, 400W\u003c\/p\u003e\n\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cp\u003eCE certified.\u003c\/p\u003e\n\n\u003c!-- FAQ --\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What's the difference between the single-pump and dual-pump LC210?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The single-pump configuration runs high-precision isocratic delivery. The dual-pump configuration adds a second pump for binary high-pressure gradient elution, with an in-line mixer for uniform blending of different mobile phases. Contact us to discuss which configuration fits your method.\"}}, {\"@type\": \"Question\", \"name\": \"What injector options are available?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The LC210 supports either a manual injector or an automatic injector, selectable based on your lab's throughput needs. Contact us for configuration options.\"}}, {\"@type\": \"Question\", \"name\": \"Does the LC210 support audit trail functionality?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The built-in workstation software supports 7\\\" touchscreen bidirectional operation, with audit-trail capability available as an add-on. Contact us to discuss documentation for your regulatory environment.\"}}]}\u003c\/script\u003e\n\n\n\u003cp\u003e\u003cstrong\u003eQ: What's the difference between the single-pump and dual-pump LC210?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The single-pump configuration runs high-precision isocratic delivery. The dual-pump configuration adds a second pump for binary high-pressure gradient elution, with an in-line mixer for uniform blending of different mobile phases. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us\u003c\/a\u003e to discuss which configuration fits your method.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What injector options are available?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The LC210 supports either a manual injector or an automatic injector, selectable based on your lab's throughput needs. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us\u003c\/a\u003e for configuration options.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Does the LC210 support audit trail functionality?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The built-in workstation software supports 7\" touchscreen bidirectional operation, with audit-trail capability available as an add-on. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us\u003c\/a\u003e to discuss documentation for your regulatory environment.\u003c\/p\u003e","brand":"Huanghai","offers":[{"title":"Single Pump","offer_id":46231937187897,"sku":"LC210-SP","price":11643.0,"currency_code":"USD","in_stock":true},{"title":"Dual Pump","offer_id":46231937220665,"sku":"LC210-DP","price":15197.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/2495\/2889\/files\/LC210_HPLC_System.jpg?v=1784641252"}],"url":"https:\/\/79dv0w-hi.myshopify.com\/collections\/hplc-systems.oembed","provider":"Huanghai Pharmaceutical Instruments","version":"1.0","type":"link"}