{"title":"Tablet Multi-Purpose Tester","description":"\u003ch2\u003eTablet Multi-Purpose Tester\u003c\/h2\u003e\n\u003cp\u003eRunning hardness, friability, disintegration, and dissolution on separate instruments means separate calibration, separate data logs, and separate footprints. Our \u003cstrong\u003eSY-6DN Intelligent 4-in-1 Tablet Tester\u003c\/strong\u003e combines all four tests in one system.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e4-in-1: hardness, friability, disintegration, and dissolution in one instrument\u003c\/li\u003e\n\u003cli\u003ePatent-backed design (CN utility model, dissolution tester family)\u003c\/li\u003e\n\u003cli\u003e3-level user management, audit trail, and USB data export\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eQC labs consolidating multiple tablet physical tests into one workflow\u003c\/li\u003e\n\u003cli\u003eLabs with limited bench space needing full tablet-testing coverage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eExplore the full lineup below to find the right solution for your lab. For quotation or technical support, \u003ca href=\"\/pages\/contact\"\u003econtact our team\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"sy-6dn-intelligent-tablet-multi-purpose-tester","title":"SY-6DN Intelligent 4-in-1 Tablet Tester – Hardness, Friability, Disintegration \u0026 Dissolution","description":"\u003c!-- PRODUCT_ID: 7815962689593 --\u003e\n\u003c!-- TITLE: SY-6DN Multi-Purpose Tablet Tester – Hardness, Friability, Disintegration \u0026 Dissolution 4-in-1 Tester --\u003e\n\u003ch2\u003e\n\u003ca name=\"_Toc187362377\"\u003e\u003c\/a\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan\u003eTablet Multi-Purpose Tester\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eSY-6DN Intelligent Tablet Multi-Purpose Tester\u003c\/p\u003e\n\u003cdiv style=\"margin:1.5rem 0;padding:1rem 1.25rem;background:#f5f9ff;border-left:3px solid #0066cc;border-radius:3px;\"\u003e\n\u003cp style=\"margin:0;\"\u003ePharmaceutical quality control instrument designed to USP \/ FDA \/ GMP standards with comprehensive audit trail support for data integrity.\u003c\/p\u003e\n\u003cp style=\"margin:0.5rem 0 0 0;\"\u003e\u003cstrong\u003eVerify our credentials:\u003c\/strong\u003e \u003ca href=\"\/pages\/certifications\" style=\"color:#0066cc;\"\u003eCertifications\u003c\/a\u003e · \u003ca href=\"\/pages\/patents\" style=\"color:#0066cc;\"\u003ePatent Portfolio\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp class=\"\" data-end=\"964\" data-start=\"764\"\u003eThe SY-6DN is a powerful \u003cstrong data-end=\"826\" data-start=\"789\"\u003epharmaceutical testing instrument\u003c\/strong\u003e designed to perform comprehensive testing of tablets, including \u003cstrong\u003ehardness\u003c\/strong\u003e, \u003cstrong\u003efriability\u003c\/strong\u003e, \u003cstrong\u003edisintegration time\u003c\/strong\u003e, and \u003cstrong\u003edissolution\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"1145\" data-start=\"971\"\u003eThis \u003cstrong data-end=\"1007\" data-start=\"976\"\u003emulti-purpose tablet tester\u003c\/strong\u003e is ideal for use in \u003cstrong data-end=\"1067\" data-start=\"1028\"\u003epharmaceutical quality control labs\u003c\/strong\u003e, combining multiple test functions into one compact and intelligent device.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"1300\" data-start=\"1152\"\u003eWith full compliance to USP standards and intuitive automation, the SY-6DN improves efficiency and data accuracy in \u003cstrong data-end=\"1287\" data-start=\"1268\"\u003etablet analysis\u003c\/strong\u003e workflows.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"1507\" data-start=\"1307\"\u003eAs part of our complete line of \u003cstrong data-end=\"1377\" data-start=\"1339\"\u003epharmaceutical testing instruments\u003c\/strong\u003e, this all-in-one tester is a perfect solution for R\u0026amp;D, formulation testing, and batch inspection in drug production environments.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eDescription\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eThe SY series intelligent tablet multi-purpose tester has been applied in the field of pharmaceutical analysis for over 40 years. It strictly complies with the current standards of the \u003cb\u003eChinese Pharmacopoeia\u003c\/b\u003e. The SY-6DN model integrates four test functionalities: \u003cb\u003edissolution testing, disintegration testing, hardness testing, and friability testing\u003c\/b\u003e. It is widely used in pharmaceutical enterprises, scientific research institutions, and higher education organizations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eProduct Features\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003e\u003cb\u003eMulti-functionality:\u003c\/b\u003e Combines dissolution testing, disintegration testing, hardness testing, and friability testing into one system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003e\u003cb\u003eEnhanced Efficiency:\u003c\/b\u003e Ideal for pharmaceutical enterprises, ensuring optimal efficiency in quality assurance processes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003e\u003cb\u003eData Security and Traceability:\u003c\/b\u003e Built-in user-level access control, audit trails, and test record management, with the ability to export reports via USB.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003e\u003cb\u003eUser-Friendly Interface:\u003c\/b\u003e Features a touch-screen control panel with bilingual (Chinese and English) operation for ease of use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003e\u003cb\u003ePrecision Control:\u003c\/b\u003e Real-time temperature monitoring, independent testing for each dissolution vessel, and precise calibration capabilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003e\u003cb\u003eRobust Design:\u003c\/b\u003e Includes modular design for quick replacement of consumables, advanced pipe routing for operational safety, and specialized medical-grade connectors for dissolving heads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003e\u003cb\u003eCustomizable Options:\u003c\/b\u003e Supports additional configurations for further customization based on user needs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003e\u003cb\u003eCompliance Certification:\u003c\/b\u003e Supplied with IQ\/OQ certification documentation for regulatory compliance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eDissolution Testing Parameters\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eSpecifications\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eNumber of Channels\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e6\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eShaft Vertical Runout\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u0026lt;0.5mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eShaft Rotation Deviation\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u0026lt;1.0mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eShaft and Cup Concentricity\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u0026lt;1.0mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eRotation Speed Range\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e10–300 RPM\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eStability\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e≤±1%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eSample Volume\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u0026lt;100mL\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eSampling Interval\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e≤9999 seconds\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eDisintegration Testing Parameters\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e \u003c\/span\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eSpecifications\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eNumber of Baskets\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e1\/6\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eTesting Frequency\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e30–32 cycles\/min\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eBasket Stroke Distance\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e55±1.0mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eMinimum Distance Between Base and Net\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e        \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e25±1.0mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eNet Aperture Diameter\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e2.0mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eTemperature Range\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eRoom Temperature to 45°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eTimer Accuracy\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e≤0.3°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eHardness Testing Parameters\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e \u003c\/span\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eSpecifications\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eTesting Range\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e10–350N\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eResolution\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e0.01N\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eAccuracy\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e±1.5%±1 digit\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eDiameter Testing Range\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e2–25mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eFriability Testing Parameters\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e \u003c\/span\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eSpecifications\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eNumber of Rotating Wheels\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e1\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eWheel Diameter\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e286mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eDefault Rotation Speed\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e25 RPM\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eSpeed Range\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e20–100 RPM\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003ePower Supply\u003c\/span\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eAC220V±10%, 50Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\" style=\"margin-top: 15px\"\u003e\n\u003cspan\u003e\n\u003cb\u003eNote:\u003c\/b\u003e Our lab instruments support basic audit trails strictly per USP\/ChP standards.\n  \u003c\/span\u003e\n\u003c\/p\u003e\n\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the USP standard for disintegration testing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Disintegration testing is governed by \u003cstrong\u003eUSP \u0026lt;701\u0026gt;\u003c\/strong\u003e (tablets and capsules) and \u003cstrong\u003eChP 0921\u003c\/strong\u003e. The test measures the time for a dosage form to break into particles small enough to pass through a specified mesh screen under simulated GI conditions. USP \u0026lt;701\u0026gt; requires testing in water or simulated gastric fluid at 37°C ± 2°C, with a reciprocating basket assembly. Huanghai LB-series testers are engineered to meet these parameters, with temperature-controlled water baths maintaining ±0.5°C accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the LB-2D and LB-3D disintegration testers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \u003ca href=\"https:\/\/drugmachines.com\/products\/lb-2d-disintegration-tester\"\u003eLB-2D\u003c\/a\u003e is a 2-station tester with a touchscreen interface—suited for small labs or single-product testing. The \u003ca href=\"https:\/\/drugmachines.com\/products\/lb-3d-intelligent-disintegration-tester\"\u003eLB-3D\u003c\/a\u003e adds a third station, enabling three simultaneous product tests, and includes an audit trail and data management system for GMP compliance. Choose LB-2D for budget-constrained or low-throughput environments; upgrade to LB-3D when your lab handles multiple formulations simultaneously or requires traceable electronic records for regulatory submissions. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us for pricing.\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does disintegration testing differ from dissolution testing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Disintegration measures whether a dosage form physically breaks apart within a specified time—it does not measure how much API is released. Dissolution (USP \u0026lt;711\u0026gt;) measures the rate and extent of API release into solution, which directly correlates with bioavailability. Disintegration is faster (typically 5–30 minutes) and is used as a routine in-process check; dissolution is the definitive QC test for bioavailability prediction. Many tablets that disintegrate quickly still have poor dissolution if the API is poorly soluble—disintegration alone is not sufficient for bioavailability assessment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the disintegration tester be used for suppositories or capsules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The LB-series testers support both tablet and capsule disintegration per USP \u0026lt;701\u0026gt;. For suppositories, the method differs—disintegration is measured using the melting time method (ChP 融变时限), which requires a different instrument: the \u003ca href=\"https:\/\/drugmachines.com\/products\/rby-n-intelligent-melting-time-tester\"\u003eRBY-N Melting Time Tester\u003c\/a\u003e. The RBY-N provides three parallel test units with adjustable rotation frequency, suitable for lipid-based suppository matrices. For complete lab capability, pair the LB-3D with the RBY-N to cover solid oral and rectal dosage forms.\u003c\/p\u003e\n\n\u003c!-- CE Certification Block — do not remove --\u003e\n\u003cdiv style=\"margin:32px 0;padding:0;border:1px solid #c8daf5;border-radius:8px;overflow:hidden;font-family:sans-serif;\"\u003e\n  \u003cdiv style=\"background:#1a3a6b;padding:14px 20px;display:flex;align-items:center;gap:14px;\"\u003e\n    \u003cspan style=\"display:inline-block;color:#fff;font-size:24px;font-weight:900;letter-spacing:-1px;border:2px solid #fff;padding:2px 8px;border-radius:3px;font-family:serif;\"\u003eCE\u003c\/span\u003e\n    \u003cspan style=\"color:#fff;font-size:15px;font-weight:600;\"\u003eCE Certified — EU Regulatory Compliant\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background:#f5f8ff;padding:18px 20px;\"\u003e\n    \u003cp style=\"margin:0 0 12px 0;font-size:13.5px;color:#333;\"\u003eThis \u003cstrong\u003eDissolution Tester\u003c\/strong\u003e is CE certified under two EU directives:\u003c\/p\u003e\n    \u003cul style=\"margin:0 0 14px 0;padding-left:20px;font-size:13px;color:#444;line-height:1.7;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMachinery Directive 2006\/42\/EC\u003c\/strong\u003e — EN ISO 12100:2010 · EN 60204-1:2018 · EN 61010-1:2010+A1:2019\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eEMC Directive 2014\/30\/EU\u003c\/strong\u003e — EN IEC 61326-1:2021\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ca href=\"\/pages\/certifications\" style=\"color:#1a5fb4;font-size:13px;font-weight:600;text-decoration:none;\"\u003eView our CE certifications →\u003c\/a\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the USP standard for disintegration testing?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Disintegration testing is governed by USP \u0026lt;701\u0026gt; (tablets and capsules) and ChP 0921. The test measures the time for a dosage form to break into particles small enough to pass through a specified mesh screen under simulated GI conditions. USP \u0026lt;701\u0026gt; requires testing in water or simulated gastric fluid at 37°C ± 2°C, with a reciprocating basket assembly. Huanghai LB-series testers are engineered to meet these parameters, with temperature-controlled water baths maintaining ±0.5°C accuracy.\"}}, {\"@type\": \"Question\", \"name\": \"What is the difference between the LB-2D and LB-3D disintegration testers?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The LB-2D is a 2-station tester with a touchscreen interface—suited for small labs or single-product testing. The LB-3D adds a third station, enabling three simultaneous product tests, and includes an audit trail and data management system for GMP compliance. Choose LB-2D for budget-constrained or low-throughput environments; upgrade to LB-3D when your lab handles multiple formulations simultaneously or requires traceable electronic records for regulatory submissions. Contact us for pricing.\"}}, {\"@type\": \"Question\", \"name\": \"How does disintegration testing differ from dissolution testing?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Disintegration measures whether a dosage form physically breaks apart within a specified time—it does not measure how much API is released. Dissolution (USP \u0026lt;711\u0026gt;) measures the rate and extent of API release into solution, which directly correlates with bioavailability. Disintegration is faster (typically 5–30 minutes) and is used as a routine in-process check; dissolution is the definitive QC test for bioavailability prediction. Many tablets that disintegrate quickly still have poor dissolution if the API is poorly soluble—disintegration alone is not sufficient for bioavailability assessment.\"}}, {\"@type\": \"Question\", \"name\": \"Can the disintegration tester be used for suppositories or capsules?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. The LB-series testers support both tablet and capsule disintegration per USP \u0026lt;701\u0026gt;. For suppositories, the method differs—disintegration is measured using the melting time method (ChP 融变时限), which requires a different instrument: the RBY-N Melting Time Tester. The RBY-N provides three parallel test units with adjustable rotation frequency, suitable for lipid-based suppository matrices. For complete lab capability, pair the LB-3D with the RBY-N to cover solid oral and rectal dosage forms.\"}}]}\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"SY-6DN Intelligent 4-in-1 Tablet Tester\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"Huanghai\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"Shanghai Huanghai Pharmaceutical Instruments Co., Ltd.\",\n    \"url\": \"https:\/\/drugmachines.com\"\n  },\n  \"category\": \"Tablet Testing Instrument \/ Pharmaceutical QC Equipment\",\n  \"description\": \"The only compact instrument combining tablet hardness, friability, disintegration and dissolution testing in one GMP-grade unit. Replaces 4 separate instruments for pharmaceutical QC labs.\",\n  \"url\": \"https:\/\/drugmachines.com\/products\/sy-6dn-intelligent-4-in-1-tablet-tester\",\n  \"offers\": {\n    \"@type\": \"Offer\",\n    \"availability\": \"https:\/\/schema.org\/InStock\",\n    \"url\": \"https:\/\/drugmachines.com\/pages\/contact\",\n    \"priceCurrency\": \"USD\",\n    \"priceSpecification\": {\n      \"@type\": \"UnitPriceSpecification\",\n      \"description\": \"Contact for pricing and specifications\"\n    }\n  }\n}\n\u003c\/script\u003e\n\u003c!-- huanghai-product-schema-v1 --\u003e\n","brand":"Huanghai","offers":[{"title":"Default Title","offer_id":44205711294521,"sku":null,"price":10120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/2495\/2889\/files\/SY-6DN-1.jpg?v=1736494785"}],"url":"https:\/\/79dv0w-hi.myshopify.com\/collections\/tablet-multi-purpose-tester.oembed","provider":"Huanghai Pharmaceutical Instruments","version":"1.0","type":"link"}