{"product_id":"lb-3d-intelligent-disintegration-tester","title":"LB-3D Intelligent Disintegration Tester – High-Performance Pharmaceutical Testing Equipment","description":"\u003c!-- PRODUCT_ID: 7815949451321 --\u003e\n\u003c!-- TITLE: LB-3D Intelligent Disintegration Tester – High-Performance Pharmaceutical Testing Equipment --\u003e\n\u003ch2\u003e\n\u003ca name=\"_Toc187362377\"\u003e\u003c\/a\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan\u003eDisintegration Instruments\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eLB-3D Intelligent Disintegration Tester\u003c\/p\u003e\n\u003cdiv style=\"margin:1.5rem 0;padding:1rem 1.25rem;background:#f5f9ff;border-left:3px solid #0066cc;border-radius:3px;\"\u003e\n\u003cp style=\"margin:0;\"\u003ePharmaceutical quality control instrument designed to USP \/ FDA \/ GMP standards with comprehensive audit trail support for data integrity.\u003c\/p\u003e\n\u003cp style=\"margin:0.5rem 0 0 0;\"\u003e\u003cstrong\u003eVerify our credentials:\u003c\/strong\u003e \u003ca href=\"\/pages\/certifications\" style=\"color:#0066cc;\"\u003eCertifications\u003c\/a\u003e · \u003ca href=\"\/pages\/patents\" style=\"color:#0066cc;\"\u003ePatent Portfolio\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded-sm px-px py-[0.2rem]\"\u003eThe LB-3D Intelligent Disintegration Tester is a state-of-the-art \u003cstrong data-end=\"103\" data-start=\"66\"\u003epharmaceutical testing instrument\u003c\/strong\u003e designed for accurate assessment of tablet and capsule disintegration times.\u003c\/span\u003e \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded-sm px-px py-[0.2rem]\"\u003eCompliant with USP and other pharmacopoeia standards, this \u003cstrong data-end=\"84\" data-start=\"59\"\u003edisintegration tester\u003c\/strong\u003e features advanced automation and user-friendly controls, making it ideal for \u003cstrong data-end=\"209\" data-start=\"162\"\u003epharmaceutical quality control laboratories\u003c\/strong\u003e.\u003c\/span\u003e \u003cspan class=\"relative -mx-px my-[-0.2rem] rounded-sm px-px py-[0.2rem]\"\u003eAs part of our comprehensive range of \u003cstrong data-end=\"76\" data-start=\"38\"\u003epharmaceutical testing instruments\u003c\/strong\u003e, the LB-3D ensures consistent and reproducible results, enhancing the efficiency of your \u003cstrong data-end=\"193\" data-start=\"166\"\u003epharmaceutical analysis\u003c\/strong\u003e processes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eDescription\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eThe LB series intelligent disintegration tester has been applied in the field of pharmaceutical analysis for over 40 years. Fully compliant with the latest \u003cb\u003eChinese Pharmacopoeia\u003c\/b\u003e standards, it is specifically designed to test the disintegration properties of solid dosage forms such as tablets, sugar-coated tablets, film-coated tablets, enteric-coated tablets, pills, and capsules under specified conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eProduct Features\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003e1. Advanced Data Management\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eBuilt-in three-tier user permissions, audit trails, and test record management.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eUSB connectivity supports direct test data export for reporting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eFrequently used data can be stored for quick and efficient use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003e2. High-Precision Temperature Control\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eReal-time temperature monitoring with dual-layer temperature protection and calibration functionality.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003ePreheating functionality allows users to schedule start times for heating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003e3. Optimized System Design\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eProfessional-grade circulation pipeline for efficient operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eFully compliant with pharmacopoeia standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003e4. Compliance and Certification\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -9.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 9.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e   \u003c\/span\u003e•\u003cspan\u003e  \u003c\/span\u003eIncludes IQ\/OQ certification documentation for validation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpFirst\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eParameter\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eSpecification\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eModel\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eLB-3D\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eProduct Number\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e10107104\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eDisintegration Stations\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e3 stations (6 tubes)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eBasket Reciprocation Speed\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e25–35 strokes\/min\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eBasket Reciprocation Range\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e55±1.0mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eMinimum Basket Distance\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e25±1.0mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eSieve Aperture\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eStandard: 0.42mm, Optional: 0.71mm, 1.0mm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eAdjustment Range\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eRoom temperature to 45.0°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eTemperature Uniformity\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e     \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e0.1°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eControl Precision\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e±0.3°C\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eCycle Limit\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u0026lt;100 cycles\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eCycle Time\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e≤999.9h\/59min59s\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003ePower Supply\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003eAC220V±10%, 50Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cem\u003eLB-3D 3-station intelligent disintegration tester with audit-trail data management — Huanghai Pharmaceutical Instruments\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 style=\"margin-top: 24px\"\u003e📄 Download User Manual\u003c\/h3\u003e\n\u003cp\u003eYou can download the full user manual of the CJY-300E High-Speed Tablet Counting Machine below:\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3 style=\"margin-top: 24px\"\u003e📄 Download User Manual\u003c\/h3\u003e\n\u003cp\u003eYou can download the full user manual of the LB-3D Intelligent Disintegration Tester below:\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0704\/2495\/2889\/files\/LB-3D_EN_V2.2.pdf?v=1749948582\" style=\"color: #007ace;text-decoration: underline\" target=\"_blank\"\u003e 📥 Click here to download LB-3D User Manual (PDF) \u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"p1\" style=\"margin-top: 15px\"\u003e\n\u003cspan\u003e\n\u003cb\u003eNote:\u003c\/b\u003e Our lab instruments support basic audit trails strictly per USP\/ChP standards.\n  \u003c\/span\u003e\n\u003c\/p\u003e\n\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the USP standard for disintegration testing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Disintegration testing is governed by \u003cstrong\u003eUSP \u0026lt;701\u0026gt;\u003c\/strong\u003e (tablets and capsules) and \u003cstrong\u003eChP 0921\u003c\/strong\u003e. The test measures the time for a dosage form to break into particles small enough to pass through a specified mesh screen under simulated GI conditions. USP \u0026lt;701\u0026gt; requires testing in water or simulated gastric fluid at 37°C ± 2°C, with a reciprocating basket assembly. Huanghai LB-series testers are engineered to meet these parameters, with temperature-controlled water baths maintaining ±0.5°C accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the LB-2D and LB-3D disintegration testers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The \u003ca href=\"https:\/\/drugmachines.com\/products\/lb-2d-disintegration-tester\"\u003eLB-2D\u003c\/a\u003e is a 2-station tester with a touchscreen interface—suited for small labs or single-product testing. The \u003ca href=\"https:\/\/drugmachines.com\/products\/lb-3d-intelligent-disintegration-tester\"\u003eLB-3D\u003c\/a\u003e adds a third station, enabling three simultaneous product tests, and includes an audit trail and data management system for GMP compliance. Choose LB-2D for budget-constrained or low-throughput environments; upgrade to LB-3D when your lab handles multiple formulations simultaneously or requires traceable electronic records for regulatory submissions. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us for pricing.\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does disintegration testing differ from dissolution testing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Disintegration measures whether a dosage form physically breaks apart within a specified time—it does not measure how much API is released. Dissolution (USP \u0026lt;711\u0026gt;) measures the rate and extent of API release into solution, which directly correlates with bioavailability. Disintegration is faster (typically 5–30 minutes) and is used as a routine in-process check; dissolution is the definitive QC test for bioavailability prediction. Many tablets that disintegrate quickly still have poor dissolution if the API is poorly soluble—disintegration alone is not sufficient for bioavailability assessment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the disintegration tester be used for suppositories or capsules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The LB-series testers support both tablet and capsule disintegration per USP \u0026lt;701\u0026gt;. For suppositories, the method differs—disintegration is measured using the melting time method (ChP 融变时限), which requires a different instrument: the \u003ca href=\"https:\/\/drugmachines.com\/products\/rby-n-intelligent-melting-time-tester\"\u003eRBY-N Melting Time Tester\u003c\/a\u003e. The RBY-N provides three parallel test units with adjustable rotation frequency, suitable for lipid-based suppository matrices. For complete lab capability, pair the LB-3D with the RBY-N to cover solid oral and rectal dosage forms.\u003c\/p\u003e\n\n\u003c!-- CE Certification Block — do not remove --\u003e\n\u003cdiv style=\"margin:32px 0;padding:0;border:1px solid #c8daf5;border-radius:8px;overflow:hidden;font-family:sans-serif;\"\u003e\n  \u003cdiv style=\"background:#1a3a6b;padding:14px 20px;display:flex;align-items:center;gap:14px;\"\u003e\n    \u003cspan style=\"display:inline-block;color:#fff;font-size:24px;font-weight:900;letter-spacing:-1px;border:2px solid #fff;padding:2px 8px;border-radius:3px;font-family:serif;\"\u003eCE\u003c\/span\u003e\n    \u003cspan style=\"color:#fff;font-size:15px;font-weight:600;\"\u003eCE Certified — EU Regulatory Compliant\u003c\/span\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"background:#f5f8ff;padding:18px 20px;\"\u003e\n    \u003cp style=\"margin:0 0 12px 0;font-size:13.5px;color:#333;\"\u003eThis \u003cstrong\u003eDisintegration Tester\u003c\/strong\u003e is CE certified under two EU directives:\u003c\/p\u003e\n    \u003cul style=\"margin:0 0 14px 0;padding-left:20px;font-size:13px;color:#444;line-height:1.7;\"\u003e\n      \u003cli\u003e\n\u003cstrong\u003eMachinery Directive 2006\/42\/EC\u003c\/strong\u003e — EN ISO 12100:2010 · EN 60204-1:2018 · EN 61010-1:2010+A1:2019\u003c\/li\u003e\n      \u003cli\u003e\n\u003cstrong\u003eEMC Directive 2014\/30\/EU\u003c\/strong\u003e — EN IEC 61326-1:2021\u003c\/li\u003e\n    \u003c\/ul\u003e\n\n    \u003ca href=\"\/pages\/certifications\" style=\"color:#1a5fb4;font-size:13px;font-weight:600;text-decoration:none;\"\u003eView our CE certifications →\u003c\/a\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the USP standard for disintegration testing?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Disintegration testing is governed by USP \u0026lt;701\u0026gt; (tablets and capsules) and ChP 0921. The test measures the time for a dosage form to break into particles small enough to pass through a specified mesh screen under simulated GI conditions. USP \u0026lt;701\u0026gt; requires testing in water or simulated gastric fluid at 37°C ± 2°C, with a reciprocating basket assembly. Huanghai LB-series testers are engineered to meet these parameters, with temperature-controlled water baths maintaining ±0.5°C accuracy.\"}}, {\"@type\": \"Question\", \"name\": \"What is the difference between the LB-2D and LB-3D disintegration testers?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The LB-2D is a 2-station tester with a touchscreen interface—suited for small labs or single-product testing. The LB-3D adds a third station, enabling three simultaneous product tests, and includes an audit trail and data management system for GMP compliance. Choose LB-2D for budget-constrained or low-throughput environments; upgrade to LB-3D when your lab handles multiple formulations simultaneously or requires traceable electronic records for regulatory submissions. Contact us for pricing.\"}}, {\"@type\": \"Question\", \"name\": \"How does disintegration testing differ from dissolution testing?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Disintegration measures whether a dosage form physically breaks apart within a specified time—it does not measure how much API is released. Dissolution (USP \u0026lt;711\u0026gt;) measures the rate and extent of API release into solution, which directly correlates with bioavailability. Disintegration is faster (typically 5–30 minutes) and is used as a routine in-process check; dissolution is the definitive QC test for bioavailability prediction. Many tablets that disintegrate quickly still have poor dissolution if the API is poorly soluble—disintegration alone is not sufficient for bioavailability assessment.\"}}, {\"@type\": \"Question\", \"name\": \"Can the disintegration tester be used for suppositories or capsules?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. The LB-series testers support both tablet and capsule disintegration per USP \u0026lt;701\u0026gt;. For suppositories, the method differs—disintegration is measured using the melting time method (ChP 融变时限), which requires a different instrument: the RBY-N Melting Time Tester. The RBY-N provides three parallel test units with adjustable rotation frequency, suitable for lipid-based suppository matrices. For complete lab capability, pair the LB-3D with the RBY-N to cover solid oral and rectal dosage forms.\"}}]}\u003c\/script\u003e","brand":"Huanghai","offers":[{"title":"Default Title","offer_id":44205686882361,"sku":null,"price":3148.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/2495\/2889\/files\/LB-3D_disintegration_tester.jpg?v=1744271853","url":"https:\/\/79dv0w-hi.myshopify.com\/products\/lb-3d-intelligent-disintegration-tester","provider":"Huanghai Pharmaceutical Instruments","version":"1.0","type":"link"}