{"product_id":"olando-k3-2-pharmaceutical-laser-drilling-system","title":"Olando K3-2 Laser Drilling System – Controlled-Release Tablet Micro-Hole Drilling Machine","description":"\u003ch2\u003e\n\u003ca name=\"_Toc187362377\"\u003e\u003c\/a\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan\u003ePharmaceutical Laser Tablet Drilling Solutions\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cem\u003eThe Olando K3-2 Pharmaceutical Laser Drilling System is developed by Huanghai Pharmaceutical Instruments — founded by the core team of China's National Pharmaceutical Engineering Research Center (NPERC) and backed by 97+ registered patents in pharmaceutical manufacturing. Trusted by pharma QC and production teams across 30+ countries for over 40 years.\u003c\/em\u003e\u003c\/p\u003e\n\n\n\u003cp\u003eOLANDO K3-2 Pharmaceutical Laser Drilling System\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"940\" data-start=\"725\"\u003eThe \u003cstrong data-end=\"781\" data-start=\"729\"\u003eOlando K3-2 Pharmaceutical Laser Drilling System\u003c\/strong\u003e is an advanced \u003cstrong data-end=\"849\" data-start=\"797\"\u003epharmaceutical testing and processing instrument\u003c\/strong\u003e designed for high-precision \u003cstrong data-end=\"907\" data-start=\"878\"\u003elaser micro-hole drilling\u003c\/strong\u003e on controlled-release tablets.\u003c\/p\u003e\n\u003cp class=\"\" data-end=\"1134\" data-start=\"945\"\u003eThis machine supports \u003cstrong data-end=\"1007\" data-start=\"967\"\u003eosmotic drug delivery systems (OROS)\u003c\/strong\u003e by enabling precise, uniform drilling of one or more micro-pores per tablet, essential for regulating drug release profiles.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eDescription:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003eThe OLANDO K3-2 sets a new benchmark in pharmaceutical manufacturing, offering a seamless combination of high-speed laser drilling, precision inspection, and defect rejection systems. Designed specifically for osmotic pump tablets, this advanced system achieves unparalleled efficiency with a production speed of up to \u003cb\u003e2,000 tablets per minute\u003c\/b\u003e. Its compliance with cGMP standards ensures reliability and quality, making it an essential tool for manufacturers aiming to streamline production while maintaining the highest quality standards. With user-friendly operation and integrated networking capabilities, the OLANDO K3-2 empowers pharmaceutical companies to achieve greater productivity and operational excellence.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eKey Features:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -15.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 15.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e     \u003c\/span\u003e1.\u003cspan\u003e      \u003c\/span\u003e\u003cb\u003eCompliance\u003c\/b\u003e: Fully adheres to cGMP regulatory requirements, ensuring manufacturing quality and safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -15.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 15.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e     \u003c\/span\u003e2.\u003cspan\u003e      \u003c\/span\u003e\u003cb\u003eHigh Speed\u003c\/b\u003e: Production speed reaches up to \u003cb\u003e2,000 tablets per minute\u003c\/b\u003e, with an inspection capacity of up to 2,500 tablets per minute, enabling unparalleled efficiency.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -15.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 15.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e     \u003c\/span\u003e3.\u003cspan\u003e      \u003c\/span\u003e\u003cb\u003eReliability\u003c\/b\u003e: Dual high-speed cameras provide precise defect detection and real-time rejection for non-conforming tablets.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -15.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 15.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e     \u003c\/span\u003e4.\u003cspan\u003e      \u003c\/span\u003e\u003cb\u003eIntelligent Control\u003c\/b\u003e: One-click operation with real-time alarms and intelligent adjustments based on system feedback, enabling automated handling with minimal human intervention.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -15.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 15.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e     \u003c\/span\u003e5.\u003cspan\u003e      \u003c\/span\u003e\u003cb\u003eEase of Use\u003c\/b\u003e: Simplified operation interface requires minimal training for operators, ensuring fast adoption and seamless production processes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"text-indent: -15.75pt;line-height: normal;margin: 9.0pt 0cm 0cm 15.75pt\"\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003e     \u003c\/span\u003e6.\u003cspan\u003e      \u003c\/span\u003e\u003cb\u003eNetworking\u003c\/b\u003e: Integrated network features allow remote data transmission, system monitoring, and maintenance, offering enhanced control and operational insights.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eTechnical Parameters:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0cm;line-height: normal\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpFirst\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eProduction Capacity\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e2,000 tablets\/min\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eCamera Maximum Recognition Time\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e    \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e40ms\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eInspection Speed\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e2,500 tablets\/min\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eQualification Rate\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e      \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e100%\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eVacuum Pressure\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e-0.1 ~ -0.3 MPa\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eCompressed Air\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e0.5 ~ 0.8 MPa\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpMiddle\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003eLaser Power\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e  \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e25W ~ 100W\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e\u003c!-- [if !supportLists]--\u003e\u003cspan style=\"color: #0e0e0e\"\u003e\u003cspan\u003el\u003cspan\u003e   \u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c!--[endif]--\u003e\u003cb\u003e\u003cspan style=\"color: #0e0e0e\"\u003ePower Supply\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"color: black\"\u003e\u003cspan\u003e       \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: #0e0e0e\"\u003e220V, 50Hz, 6kW\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoListParagraphCxSpLast\" style=\"text-indent: -22.0pt;line-height: normal;margin: 0cm 0cm 0cm 22.0pt\"\u003e \u003c\/p\u003e\n\u003c!-- Case Studies Footer Link --\u003e\n\u003cdiv style=\"margin-top: 32px;text-align: center\"\u003e\n\u003cp style=\"margin-bottom: 12px\"\u003e\u003cstrong\u003eWant to see it in action?\u003c\/strong\u003e\u003c\/p\u003e\n\u003ca href=\"\/pages\/laser-drilling-solution-for-osmotic-tablets\" style=\"padding: 10px 18px;background-color: #000;color: #fff;text-decoration: none;border-radius: 6px\"\u003e View Real-World Pharma Applications → \u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp class=\"p1\" style=\"margin-top: 15px\"\u003e\n\u003cspan\u003e\n\u003cb\u003eNote:\u003c\/b\u003e Our lab instruments support basic audit trails strictly per USP\/ChP standards.\n  \u003c\/span\u003e\n\u003c\/p\u003e\n\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does laser drilling create controlled-release tablets?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Laser drilling creates a precise aperture (typically 0.3–1.2mm diameter) in the tablet coating, forming the drug delivery orifice for osmotic pump tablet systems (OROS technology). The osmotic pressure differential between the tablet core and gastrointestinal fluids drives API release through this aperture at a controlled rate. Hole diameter, depth (blind vs. through-hole), and position are critical parameters—variations of ±0.1mm or more can significantly alter release kinetics. The \u003ca href=\"https:\/\/drugmachines.com\/products\/olando-k3-2-pharmaceutical-laser-drilling-system\"\u003eOlando K3-2\u003c\/a\u003e maintains ±0.1mm accuracy at 120,000 tablets\/hour using closed-loop vision detection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between blind holes and through-holes in osmotic tablets?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Through-holes penetrate the entire tablet coating, creating bidirectional flow. Blind holes penetrate only the tablet coat (not the core), creating a single-direction orifice. Most OROS formulations (e.g., Nifedipine CR, Doxazosin Mesylate) use a single blind hole on the coat surface, preserving core integrity while enabling precise osmotic release. Blind holes require tighter laser parameter control because the laser must stop within the coating layer—the Olando K3-2's Siemens PLC-controlled laser delivery system ensures consistent hole depth within ±0.05mm, preventing API core exposure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What tablet shapes and sizes can the Olando K3-2 process?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The Olando K3-2 handles \u003cstrong\u003eround tablets (bilayer and single-layer)\u003c\/strong\u003e with adjustable feed channel geometry. Standard configurations support tablet diameters from approximately 6mm to 20mm, covering the vast majority of osmotic tablet designs for cardiovascular, CNS, and metabolic indications. The system processes 120,000 tablets\/hour (single aperture configuration), equivalent to approximately 2 billion tablets annually on a standard 24\/7 production schedule. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eContact us\u003c\/a\u003e with your specific tablet dimensions for configuration confirmation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does laser drilling comply with FDA 21 CFR Part 11?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The Olando K3-2 Laser Drilling System is designed for cGMP environments and includes Siemens PLC-based process control with audit trail functionality—recording all parameter changes, operator interventions, and batch data in tamper-evident electronic records. This supports compliance with \u003cstrong\u003eFDA 21 CFR Part 11\u003c\/strong\u003e and \u003cstrong\u003eEU Annex 11\u003c\/strong\u003e data integrity requirements. For full Part 11 compliance, integrate the system's data outputs into a validated manufacturing execution system (MES) or LIMS. Reference customers include Shanghai Modern Pharmaceutical (12 installed units for Nifedipine CR) and Shanghai Xinyi Pharmaceutical (3 units for Doxazosin Mesylate).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the ongoing maintenance requirements for laser drilling equipment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Key maintenance items for the Olando K3-2: (1) Laser source service interval: approximately every 10,000 operating hours (roughly 14 months at 24\/7 operation); (2) Vision system calibration: recommended every 3–6 months or after any process parameter change; (3) Optics cleaning: weekly inspection, cleaning as needed based on particulate environment. Preventive maintenance should be incorporated into your equipment qualification protocol (IQ\/OQ\/PQ). Huanghai provides remote diagnostics support and on-site service through our Singapore operations hub. \u003ca href=\"https:\/\/drugmachines.com\/pages\/contact\"\u003eRequest our service agreement terms.\u003c\/a\u003e\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"How does laser drilling create controlled-release tablets?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Laser drilling creates a precise aperture (typically 0.3–1.2mm diameter) in the tablet coating, forming the drug delivery orifice for osmotic pump tablet systems (OROS technology). The osmotic pressure differential between the tablet core and gastrointestinal fluids drives API release through this aperture at a controlled rate. Hole diameter, depth (blind vs. through-hole), and position are critical parameters—variations of ±0.1mm or more can significantly alter release kinetics. The Olando K3-2 maintains ±0.1mm accuracy at 120,000 tablets\/hour using closed-loop vision detection.\"}}, {\"@type\": \"Question\", \"name\": \"What is the difference between blind holes and through-holes in osmotic tablets?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Through-holes penetrate the entire tablet coating, creating bidirectional flow. Blind holes penetrate only the tablet coat (not the core), creating a single-direction orifice. Most OROS formulations (e.g., Nifedipine CR, Doxazosin Mesylate) use a single blind hole on the coat surface, preserving core integrity while enabling precise osmotic release. Blind holes require tighter laser parameter control because the laser must stop within the coating layer—the Olando K3-2's Siemens PLC-controlled laser delivery system ensures consistent hole depth within ±0.05mm, preventing API core exposure.\"}}, {\"@type\": \"Question\", \"name\": \"What tablet shapes and sizes can the Olando K3-2 process?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The Olando K3-2 handles round tablets (bilayer and single-layer) with adjustable feed channel geometry. Standard configurations support tablet diameters from approximately 6mm to 20mm, covering the vast majority of osmotic tablet designs for cardiovascular, CNS, and metabolic indications. The system processes 120,000 tablets\/hour (single aperture configuration), equivalent to approximately 2 billion tablets annually on a standard 24\/7 production schedule. Contact us with your specific tablet dimensions for configuration confirmation.\"}}, {\"@type\": \"Question\", \"name\": \"Does laser drilling comply with FDA 21 CFR Part 11?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The Olando K3-2 Laser Drilling System is designed for cGMP environments and includes Siemens PLC-based process control with audit trail functionality—recording all parameter changes, operator interventions, and batch data in tamper-evident electronic records. This supports compliance with FDA 21 CFR Part 11 and EU Annex 11 data integrity requirements. For full Part 11 compliance, integrate the system's data outputs into a validated manufacturing execution system (MES) or LIMS. Reference customers include Shanghai Modern Pharmaceutical (12 installed units for Nifedipine CR) and Shanghai Xinyi Pharmaceutical (3 units for Doxazosin Mesylate).\"}}, {\"@type\": \"Question\", \"name\": \"What are the ongoing maintenance requirements for laser drilling equipment?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Key maintenance items for the Olando K3-2: (1) Laser source service interval: approximately every 10,000 operating hours (roughly 14 months at 24\/7 operation); (2) Vision system calibration: recommended every 3–6 months or after any process parameter change; (3) Optics cleaning: weekly inspection, cleaning as needed based on particulate environment. Preventive maintenance should be incorporated into your equipment qualification protocol (IQ\/OQ\/PQ). Huanghai provides remote diagnostics support and on-site service through our Singapore operations hub. Request our service agreement terms.\"}}]}\u003c\/script\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"Olando K3-2 Laser Drilling System\",\n  \"brand\": {\n    \"@type\": \"Brand\",\n    \"name\": \"Huanghai\"\n  },\n  \"manufacturer\": {\n    \"@type\": \"Organization\",\n    \"name\": \"Shanghai Huanghai Pharmaceutical Instruments Co., Ltd.\",\n    \"url\": \"https:\/\/drugmachines.com\"\n  },\n  \"category\": \"Pharmaceutical Laser Drilling Machine \/ Controlled-Release Equipment\",\n  \"description\": \"Precision laser micro-drilling machine for controlled-release tablet manufacturing. Creates micro-holes in osmotic pump tablets with ±0.1mm accuracy. GMP-grade pharmaceutical laser equipment.\",\n  \"url\": \"https:\/\/drugmachines.com\/products\/olando-k3-2-pharmaceutical-laser-drilling-system\",\n  \"offers\": {\n    \"@type\": \"Offer\",\n    \"availability\": \"https:\/\/schema.org\/InStock\",\n    \"url\": \"https:\/\/drugmachines.com\/pages\/contact\",\n    \"priceCurrency\": \"USD\",\n    \"priceSpecification\": {\n      \"@type\": \"UnitPriceSpecification\",\n      \"description\": \"Contact for pricing and specifications\"\n    }\n  }\n}\n\u003c\/script\u003e\n\u003c!-- huanghai-product-schema-v1 --\u003e\n","brand":"Huanghai","offers":[{"title":"Default Title","offer_id":44205830602809,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0704\/2495\/2889\/files\/olando-k3-2-laser-drilling-front.png?v=1744301017","url":"https:\/\/79dv0w-hi.myshopify.com\/products\/olando-k3-2-pharmaceutical-laser-drilling-system","provider":"Huanghai Pharmaceutical Instruments","version":"1.0","type":"link"}